SINGLE DOOR MAGNETIC LOCK
INSTALLATION INSTRUCTIONS
USER MANUAL
0E-MAG600LB (600 lbs.)
0E-MAG1200LB (1200 lbs.)
ENGLISH
TABLE OF CONTENTS
Introduction...................................................2
Safety and Compliance................................3
Installation and Maintenance.....................4
Wiring.............................................................7
Troubleshooting...........................................9
Warranty......................................................10
MANUEL D’UTILISATION
0E-MAG600LB (600 lbs.)
0E-MAG1200LB (1200 lbs.)
FRANÇAIS
Introduction................................................12
Sécurité et Conformité...............................13
Installation et Maintenance.......................14
Câblage.............................................17
Dépannage.......................................19
Garantie.....................................................20
TABLE DES MATIÈRES

Questions and Answers

  • L
    Lisa RandallAug 10, 2025
    Why is my ADI PRO 0E-MAG600LB maglock extremely hot to the touch?
    • D
      Dr. Rebecca Pollard DDSAug 10, 2025
      To address a maglock (magnetic lock) by ADI PRO from the Locks category that's extremely hot to the touch, first, check the power supply. If the maglock is set to 12VDC but receiving 24VDC, adjust the power supply to 12VDC. Also, inspect the cables for any induced power and eliminate it.
  • K
    Kevin SteinAug 15, 2025
    What to do if ADI PRO Locks maglock secures at the power supply but not in the installed location?
    • S
      Shannon CampbellAug 15, 2025
      If your ADI PRO Locks maglock secures at the power supply but not when installed, it might be due to the cable. Always use 18-gauge solid wire for power cable runs. Thinner cable gauges, such as 22, 24, and CAT5/6, aren't sufficient for providing power over longer distances, so avoid using them. Additionally, check the wire for any breaks.
  • K
    Kevin HartAug 20, 2025
    How to fix low holding force on ADI PRO Locks maglock?
    • D
      delgadohunterAug 20, 2025
      If your ADI PRO Locks maglock has low holding force, the issue might be with the power supply or the armature plate alignment. Ensure the power supply matches the maglock requirements; if the maglock is set to 24VDC, the power supply should also be 24VDC. Also, realign the armature plate to ensure complete coverage. Finally, if you're using an unregulated/unfiltered power supply, switch to a regulated and filtered one.
  • M
    Morgan WilsonAug 25, 2025
    What to do if ADI PRO 0E-MAG600LB Locks maglock secures, but neither the door contact nor the bond sensor change state?
    • V
      villahollyAug 25, 2025
      If your ADI PRO Locks maglock secures, but neither the door contact nor the bond sensor change state, the magnet on the armature plate might be incorrectly positioned. Reposition the magnet on the armature plate. Also, ensure the armature plate makes complete contact.
  • J
    Joy HooperAug 30, 2025
    How to use varistor with ADI PRO Locks maglock?
    • J
      Joseph MartinezAug 30, 2025
      To prevent intermittent operation with your ADI PRO Locks maglock, install the varistor directly on the power inputs of the maglock. The varistor acts as a load to eliminate any residual power left when power is dropped. A maglock is a large coil, and when down powered, it will try to lose the built up energy (residual power stored in the coil of the maglock). This will send residual voltage down the line back to the controlling device and cause intermittent operation.
  • R
    Rhonda HarperSep 4, 2025
    How to make ADI PRO 0E-MAG600LB Locks maglock drop power during a fire test or fire event?
    • P
      Peter EvansSep 4, 2025
      To ensure your ADI PRO Locks maglock drops power during a fire test or fire event, make sure you are using a fire-rated power supply connected to the fire alarm panel.

ADI PRO 0E-MAG600LB Specifications

General IconGeneral
TypeElectromagnetic Lock
Holding Force600 lbs
Voltage12/24 VDC
FinishAnodized Aluminum
MountingSurface Mount
Current500mA at 12VDC, 250mA at 24VDC
Operating Temperature14 to 131° F (-10 to 55° C)