    bradhaneySep 4, 2025
    What does 'Source of speed command error' mean for Adleepower DC Drives?
    • K
      Kevin WilliamsSep 4, 2025
      If you encounter a 'Source of speed command error' with your Adleepower DC Drives, it means the system is set at analog command, but the F306 keypad is being used to change the speed. Use CD19 to change the setting.
  • Z
    zarmstrongSep 18, 2025
    What does 'Read only parameter' mean for Adleepower AM-120M?
    • V
      Victor CharlesSep 18, 2025
      If a parameter is 'Read only' on your Adleepower DC Drives, it means the parameter was created by the system and cannot be changed by the user.
  • J
    Joseph MedinaSep 16, 2025
    Why can parameter only be changed in standby on Adleepower AM-120M DC Drives?
    • C
      Chad Smith MDSep 16, 2025
      The parameter on Adleepower DC Drives can only be changed in standby mode because of system settings.
  • J
    Jeffrey MorrisonSep 14, 2025
    What does 'Over range error' mean on Adleepower DC Drives?
    • C
      Christopher SimpsonSep 14, 2025
      An 'Over range error' on Adleepower DC Drives indicates an operating error message due to being over range.
  • K
    Karen WilsonSep 12, 2025
    What does 'Logic error warning' mean on Adleepower AM-120M DC Drives?
    • B
      Benjamin MooreSep 12, 2025
      A 'Logic error warning' on Adleepower DC Drives indicates a logic error during setting, for example, CD05 > CD04.
  • L
    Larry BanksSep 12, 2025
    Why is Adleepower DC Drives only running FWD or REV?
    • N
      nicolebergSep 12, 2025
      If your Adleepower DC Drives are only running in FWD or REV, it is due to the motor direction limiter. Refer to function description CD18 for more details.
  • E
    Eric JacksonSep 9, 2025
    What to do if Adleepower AM-120M are in 'Parameter lock'?
    • M
      Michael DawsonSep 9, 2025
      If your Adleepower DC Drives are in 'Parameter lock', set CD00 to 1.
  • J
    Jay ArmstrongSep 7, 2025
    What to do if Adleepower AM-120M DC Drives display 'Hall sensor fail'?
    • C
      cchenSep 7, 2025
      If your Adleepower DC Drives display 'Hall sensor fail', check the wire and plug connections between the motors and drives.
  • J
    Julie YoungSep 5, 2025
    What does 'Source of operation command error' mean for Adleepower DC Drives?
    • J
      Joseph BrooksSep 5, 2025
      If you are getting a 'Source of operation command error' on your Adleepower DC Drives, it indicates that terminal control, F306, and RS485 cannot be used simultaneously. Use the jumper to change the setting.
  • L
    Linda StevensonAug 21, 2025
    What to do if my Adleepower AM-120M DC Drives show driver overheat, over voltage, or over current?
    • T
      Tammy JohnsonAug 21, 2025
      If your Adleepower DC Drives are showing driver overheat, over voltage, or over current, you should: * Check the input voltage to ensure it's not too high. * Check the cooling condition of the drives. * Check the motor loading to ensure it's not overloaded. * Inspect the wiring and plugs between the motors and drives for any U, V, W shortages. * Examine the acceleration and deceleration time settings. * Verify the CW, CCW, and stop operation frequency. * Check the inertial load, as the motors may be getting traction from the loading.

Summary

Preface and Safety Precautions

Safety Warnings and Handling

Details potential hazards, warnings, and safe handling practices for the equipment.

Product Overview and Specifications

Technical Specifications

Comprehensive data on motor and drive ratings, performance, and features.

Terminals and Wiring

Main and Control Terminal Layouts

Identifies and describes main circuit and control terminals.

Control Terminal Details and Jumpers

Detailed descriptions of control terminals and jumper configurations.

Operation and Parameter Management

Parameter Setting Procedure

Step-by-step guide for changing parameter values.

Detailed Parameter Descriptions

Troubleshooting and Error Resolution

Error Code Analysis and Solutions

Guide to diagnosing and resolving common error codes and operational faults.

Adleepower AM-120M Specifications

General IconGeneral
BrandAdleepower
ModelAM-120M
CategoryDC Drives
LanguageEnglish

Related product manuals