8
CopyrightADSInstallationManualModelETAFPDH,Revision3.1,5/25/2017
CHEMICALFEEDERSSECTION

Youmustwearapprovedsafetyeyewearbeforeconnectingchemicals.Readthechemicalmanufacturer’s
MSDSsheets.Chemicalscandamageorcorrodeplumbingandstainlesspartsofthedishmachine.Donot
runchemicallinesovercontrolsorplumbing.Alwayssecurechemicallinesandcheckregularlyforleaks.If
notproperlyhandled,chemicalscancauseseriousbodilyinjury.Intheeventofchemicalcontacttoskinor
eyes;washimmediatelywithfreshwaterandseekmedicalattention.
INSTRUCTIONSFORDELIME,Onlyperformedbytrainedchemicalspecialists.First,emptyallwateroutofthe
machinebypushingthedrainbutton.Afterallwaterhasemptiedout,fillthemachinewithfreshwater.
After,turnoffthemasterswitch.Disconnectandprotectoneofthewirestothecamtimermotorandrollthe
camtimertomidcycleonthewashsection.Turnonthemasterswitchtooperatethepumpmotor.Addde
limeagenttothefreshtankwater.Repeatthisfirststepagainbydraining,thenrefillandthenrunwithfresh
water.Thiswillflushthemachine,thenturnoffthemasterswitchandreconnectthetimermotorwirefor
normalcycles.READTHEDIRECTIONSONTHECONTAINERFORCORRECTCONCENTRATIONOFTHE
CHEMICAL.TYPICALCONCENTRATIONLEVELS1:20to1:60.
Itisbesttodelimemoreoftenwithmilderacidsolutionsthanwaitinguntilthereisheavybuildupofwhite
minerals,thentryingtoremovethebuildupwithverystrongacidconcentrations.Usingtoostrongofanacid
solutionorrunningitforverylongperiodsoftime willerodethemetaloftheimpellerbecauseitisspinningin
theacidsolution.
 
WarningdecalaboutmixingchemicalsImpellerdamagedfromhighacidsolution
WARNING