CopyrightADSInstallationManualModelET‐AF‐PDH,Revision3.1,5/25/2017
CHEMICALFEEDERSSECTION

Youmustwearapprovedsafetyeye‐wearbeforeconnectingchemicals.Readthechemicalmanufacturer’s
MSDSsheets.Chemicalscandamageorcorrodeplumbingandstainlesspartsofthedishmachine.Donot
runchemicallinesovercontrolsorplumbing.Alwayssecurechemicallinesandcheckregularlyforleaks.If
notproperlyhandled,chemicalscancauseseriousbodilyinjury.Intheeventofchemicalcontacttoskinor
eyes;washimmediatelywithfreshwaterandseekmedicalattention.
INSTRUCTIONSFORDE‐LIME,Onlyperformedbytrainedchemicalspecialists.First,emptyallwateroutofthe
machinebypushingthedrainbutton.Afterallwaterhasemptiedout,fillthemachinewithfreshwater.
After,turnoffthemasterswitch.Disconnectandprotectoneofthewirestothecamtimermotorandrollthe
camtimertomid‐cycleonthewashsection.Turnonthemasterswitchtooperatethepumpmotor.Addde‐
limeagenttothefreshtankwater.Repeatthisfirststepagainbydraining,thenrefillandthenrunwithfresh
water.Thiswillflushthemachine,thenturnoffthemasterswitchandreconnectthetimermotorwirefor
normalcycles.READTHEDIRECTIONSONTHECONTAINERFORCORRECTCONCENTRATIONOFTHE
CHEMICAL.TYPICALCONCENTRATIONLEVELS1:20to1:60.
Itisbesttode‐limemoreoftenwithmilderacidsolutionsthanwaitinguntilthereisheavybuildupofwhite
minerals,thentryingtoremovethebuildupwithverystrongacidconcentrations.Usingtoostrongofanacid
solutionorrunningitforverylongperiodsoftime willerodethemetaloftheimpellerbecauseitisspinningin
theacidsolution.
 
WarningdecalaboutmixingchemicalsImpellerdamagedfromhighacidsolution