Aduro H1, H2, H3 LUX, H4 LUX & H5
EN13240 - EN14785 - NS3058 - Ecodesign 2022
aduro.dk / adurofire.com
Betjeningsvejledning
Bedienungsanleitung
User Manual
DA/NO (2-25)
Eldningsinstruktion
DE (26-51)
EN (52-76)
SE (77-100)

Other manuals for ADURO H1

Questions and Answers

  • C
    Christopher StephensAug 13, 2025
    Why my ADURO Pellet stove app does not connect to the stove?
    • E
      Elizabeth BarrAug 13, 2025
      If the ADURO Pellet stove app isn't connecting, the issue might be due to a connection problem. Verify your Wi-Fi connection. If the connection is active, try restarting the app and reconnecting.
  • R
    Robert DavisAug 17, 2025
    What to do if ADURO Pellet stove shows 'Alarm: no more pellet'?
    • J
      Justin MartinAug 17, 2025
      If your ADURO Pellet stove displays the 'Alarm: no more pellet' message, it means that the stove has run out of pellets. Simply refill the tank with new pellets.
  • W
    William MooreAug 21, 2025
    Why ADURO H1 pellet combustion is deactivated after loading wood?
    • A
      Andrew WilliamsAug 21, 2025
      The pellet combustion on your ADURO Pellet stove might be disabled after loading wood because the door is not closed correctly. Check the closing mechanism and the sensor. Another reason might be that the door remained open for more than 3 minutes; it must be closed sooner to prevent deactivation.
  • J
    Joshua MosleyAug 25, 2025
    What to do if ADURO H1 Pellet stove shows 'Alarm: cannot light up'?
    • C
      Craig RodriguezAug 26, 2025
      If your ADURO Pellet stove displays the alarm 'cannot light up', this may be due to a lack of adequate draft. Check the installation and draft.
  • J
    Jamie BurkeAug 28, 2025
    Why ADURO Pellet stove pellet combustion is deactivated after burning the wood?
    • J
      Jeffrey CampbellAug 29, 2025
      The pellet combustion might be deactivated on your ADURO Pellet stove after burning wood if the smoke temperature exceeds 50°C. Once the smoke temperature drops below 50°C, the pellet combustion will resume automatically.
  • D
    Daniel ThomasSep 1, 2025
    How to fix false 'no more pellet' alarm on ADURO H1 Pellet stove?
    • D
      Daniel MooneySep 1, 2025
      If your ADURO Pellet stove is showing a false 'no more pellet' alarm, and combustion stops after 60 minutes, it could be due to a weak or insufficient draft. Check the installation and draft. Alternatively, the stove may not be reaching the expected temperature for the selected power level. In this case, position the air regulator to position 5.
  • T
    teresa32Sep 5, 2025
    Why is the glass on my ADURO Pellet stove very dirty or blackened?
    • J
      Johnny JonesSep 5, 2025
      If the glass on your ADURO Pellet stove is getting very dirty or blackened, it could be due to insufficient draft. Verify the installation and draft. Another possible cause is that the glass cleaning function is deactivated. Adjust the air regulator to a setting between 2 and 4 when burning wood.
  • A
    Adam WilliamsSep 8, 2025
    Why does pellet accumulate in the burner of my ADURO H1?
    • J
      John Welch DVMSep 8, 2025
      If pellet is accumulating in the burner of your ADURO Pellet stove, it could be due to a lack of adequate draft. Check the installation and the draft. Another cause could be that the burner cover is not correctly aligned. Inspect the burner alignment.

Summary

General Information and Compliance

1.2 Warnings and Safety Precautions

Crucial safety information and warnings for operating the Aduro hybrid stove.

Installation of the Stove

2.1 Position and Distance Requirements

Specifies safe distances to flammable materials for stove placement.

2.2 Pipe Connection

Instructions for connecting the flue pipe to the stove and chimney.

Operating the Hybrid Stove

3.2.1 Configuration of the App

Steps to connect the stove and set up the Aduro Hybrid app.

Firing in the Hybrid Stove

4.1 Firing with Wood

Instructions and tips for lighting and maintaining a wood fire.

4.1.3.1 Lighting the Fire Manually with Firewood

Detailed steps for manually lighting a fire with firewood.

4.2 Firing with Pellets

Instructions for operating the stove using only wood pellets.

4.2.2 Lighting the Fire with Pellets

Steps for igniting the stove using pellets via control panel or app.

The Chimney System

5.1 Inadequate Draft in the Chimney

Troubleshooting common issues related to insufficient chimney draft.

5.2 Chimney and Smoke Issues

Addressing smoke issues and cold plugs in the chimney.

Important Alarms

Cleaning and Maintenance

7.4 Yearly Service Visit

Requirements for annual inspection and maintenance by a certified professional.

Spare Parts and Unauthorized Alterations

ADURO H1 Specifications

General IconGeneral
CategoryPellet stove
Diameter smoke outlet (mm)80
Fuel TypeWood Pellets
Ignition TypeAutomatic
ThermostatYes