USER MANUAL
AD11 & AD12
Waterproof pH Testers
Dear Customer,
Thank you for choosing an Adwa product.
Please read carefully this manual before
starting operations.
These instruments are in compliance with the
EMC Directive 89/336/EEC and Low Voltage
Directive 73/23/EEC for electrical equipments.
For additional technical information, please
e-mail us at sales@adwainstruments.com.
INTRODUCTION
AD11 and AD12 are waterproof pH and
temperature testers. The housing has been
completely sealed against humidity.
All pH readings are automatically temperature
compensated (ATC), and temperature values
can be displayed in °C or °F units.
The meter can be calibrated at one or two
points for pH with auto-buffer recognition
and against five memorized buffer values.
Measurements are highly accurate with a
unique stability indicator right on the LCD.
The models are also provided with a low
battery symbol which warns the user when
the batteries need to be replaced.
The AD11P pH electrode, supplied with the
meter, is interchangeable and can be easily
replaced by the user.
The encapsulated temperature sensor allows
fast and accurate temperature measurement
and compensation.
Each meter is supplied complete with:
AD11P pH electrode
4 x 1.5V batteries, button type
User manual
FRONT PANEL & DISPLAY
1. Dual line LCD
2. ON/OFF/ MODE button
3. pH electrode & temperature sensor
4. Electrode body
5. Battery compartment (inside)
6. SET/HOLD button
7. Clip holder
1. Stability indicator (hourglass symbol)
2. Low battery warning indicator
3. Calibration mode / calibrated meter indication
4. ATC (Automatic Temperature Compensation)
indicator
5. Secondary LCD level
6. Primary LCD level
7. Measurement unit for primary level
TECHNICAL DATA
Range -2.0 to 16.0 pH (AD11)
-2.00 to 16.00 pH (AD12)
-5.0 to 60.0°C / 23.0 to 140.0°F
Resolution 0.1 / 0.01 pH
0.1°C / 0.1°F
Accuracy (@20°C/68°F)
±0.1 / ±0.01 pH
±0.5°C / ±1°F
pH Calibration
Automatic, 1 or 2 point
with 2 sets of memorized buffers
(pH 4.01/7.01/10.01 or 4.01/6.86/9.18)
pH Electrode AD11P (included)
Temperature Compensation
Automatic
Battery Type 4 x 1.5V button type
Battery Life Approx. 300 h of use
Auto-off After 8 minutes of non-use
Environment
-5 to 50°C (23 to122°F); RH 100%
Dimensions 175.5 x 39 x 23 mm
Weight 100 g
AD11P Spare pH electrode
A70004P pH 4.01 buffer, 20 ml, 25 pcs
A7004M pH 4.01 buffer, 230 ml bottle
A70007P pH 7.01 buffer, 20 ml, 25 pcs
A7007M pH 7.01 buffer, 230 ml bottle
A70010P pH 10.01 buffer, 20 ml, 25 pcs
A7010M pH 10.01 buffer, 230 ml bottle
A7061M Electrode cleaning solution,
230 ml
A70300M Storage solution, 230 ml
ELECTRODES & SOLUTIONS
ISTAD12 04/10
Question and Answer IconNeed help?

Do you have a question about the ADWA AD11 and is the answer not in the manual?

ADWA AD11 Specifications

General IconGeneral
TypepH/mV/Temperature Meter
pH Resolution0.01 pH
Temperature Resolution0.1°C / 0.1°F
Temperature Accuracy±0.5°C / ±1°F
mV Resolution1 mV
pH Calibration2 or 3 points
Temperature CompensationAutomatic
ProbeReplaceable pH electrode
Environment0 to 50 °C; RH max 95%

Summary

Introduction

Front Panel & Display Overview

Technical Data

Electrodes & Solutions

Operational Guide

Turn the Meter On

Instructions on how to power on the pH meter by pressing the ON/OFF/ MODE button until the LCD lights up.

Freeze the Display

Procedure to freeze the current pH or temperature reading on the LCD.

Turn the Meter Off

Steps to switch off the pH meter using the ON/OFF/MODE button.

pH Measurement & Calibration

Taking Measurement

Guide on how to submerge the electrode and wait for the stability indicator.

pH Calibration Procedure

Detailed steps for performing pH calibration, including buffer recognition.

Single-Point Calibration

Instructions for calibrating the meter using a single buffer point.

Two-Point Calibration

Procedure for a two-point calibration for improved measurement accuracy.

Quit Calibration & Reset

How to exit calibration mode or reset calibration settings to defaults.

Setup Menu

Temperature Unit Selection (°C/°F)

Instructions on how to select the temperature unit (°C or °F) in the setup menu.

Calibration Buffer Set Selection

Guide to changing the memorized buffer sets for pH calibration.

Electrode Maintenance

Battery Replacement

Related product manuals