WARNING: The appliance and its accessible parts become
hot during use. Care should be taken to avoid touching
heating elements or the surface of the appliance cavity.
Always use oven gloves to remove or insert accessories or
ovenware.
Do not use a steam cleaner to clean the appliance.
Do not use harsh abrasive cleaners or sharp metal scrapers
to clean the glass door since they can scratch the surface,
which may result in shattering of the glass.
Before pyrolytic cleaning, remove all accessories and
excessive deposits/spills from the appliance cavity.
2. SAFETY INSTRUCTIONS
2.1 Installation
WARNING!
Only a qualified person must install this
appliance.
Remove all the packaging.
Do not install or use a damaged
appliance.
Follow the installation instructions supplied
with the appliance.
Always take care when moving the
appliance as it is heavy. Always use safety
gloves and enclosed footwear.
Do not pull the appliance by the handle.
Install the appliance in a safe and suitable
place that meets installation requirements.
Keep the minimum distance from other
appliances and units.
Before mounting the appliance, check if
the appliance door opens without restraint.
The appliance is equipped with an electric
cooling system. It must be operated with
the electric power supply.
Cabinet minimum height
(Cabinet under the worktop
minimum height)
590 (600) mm
Cabinet width 560 mm
Cabinet depth 550 (550) mm
Height of the front of the
appliance
594 mm
Height of the back of the
appliance
576 mm
Width of the front of the ap‐
pliance
595 mm
Width of the back of the ap‐
pliance
559 mm
Depth of the appliance 569 mm
Built in depth of the appli‐
ance
548 mm
Depth with open door 1022 mm
Ventilation opening mini‐
mum size. Opening placed
on the bottom rear side
560x20 mm
Mains supply cable length.
Cable is placed in the right
corner of the back side
1500 mm
Mounting screws 4x25 mm
2.2 Electrical connection
WARNING!
Risk of fire and electric shock.
All electrical connections should be made
by a qualified electrician.
The appliance must be earthed.
Make sure that the parameters on the
rating plate are compatible with the
4 ENGLISH