Troubleshooting
PROBLEM
CAUSE
REMEDY
‘The
air-
conditioner
does
not
function
The
air-conditioner
functions
for
a
brief
period
only,
because
the
safety
circuit-breaker
has
been
tripped.
The
®
pilot
lamp
flashes
The
appliance
constantly
blows
the
fuses
if
the
©
pilot
lamp
is
not
lit
-
power
failure
-
the
appliance
is
not
plugged
in
if
the
Memo
Control
pilot
lamp
is
flashing
-
less
than
3
minutes
have
passed
since
the
appliance
was
last
switched
off
if
the
Conditioning
lamp
is
flashing
-
inconditioning
mode:
the
temperature
in
the
room
is
lower
than
the
selected
temperature
if
the
Heating
lamp
is
flashing
-
inheating
mode:
the
temperature
in
the
room
is
higher
than
the
selected
tempe-
-
rature
ifthe
B@
FULL
pilot
lamp
is
lit
-
the
condensation
canister
is
full
-
‘the
condensation
canister
is
not
fitted
properly
the
exhaust
hose
is
obstructed
the
exhaust
hose
is
kinked
the
safety
float
has
switched
the
appliance
off
the
condenser
fan
has
jammed
the
control
circuit
board
is
faulty
The
air-
conditioner
functions
but
the
room
is
not
cooled:
The
air-
conditioner
does
not
heat
the
room
TECHNICAL
ASSISTANCE
®
window
open
source
of
heat
in
the
room.
(heater,
lamp
etc.)
or
the
room
is
very
crowded
the
air
exhaust
hose
has
become
detached
the
thermostat
is
set
too
high
the
air
filter
is
dirty
the
air-conditioner
is
not
powerful
enough
for
the
size
or
the
conditions
of
the
room
the
safety
thermostat
which
protects
the
heating
element
has
intervened
e
waituntil
the
power
supply
is
restored
e
insert
the
plug
wait
three
minutes
turn
the
thermostat
knob
slowly
to
the
maximum
cooling
position.
e
turn
the
thermostat
knob
slowly
to
the
maximum
heating
position
empty
the
canister
and
restart
the
appliance
fit
the
canister
remove
any
obstruction
from
the
air
exhaust
hose.
¢
position
the
hose
correctly.
Press
the
on/off
switch
twice
e
drain
the
condensation
from
the
tray
through
the
drainage
tube.
If
this
fault
persists,
contact
your
nearest
Service
Centre
|
e
contact
your
nearest
Service
Centre
e
contact
your
nearest
Service
Centre
switch
the
appliance
off
and
contact
your
nearest
Service
Centre
close
the
window
remove
source
of
heat
re-attach
the
air
exhaust
hose
e
lower
the
thermostat
setting
clean
the
filter
to
restart
the
appliance,
remove
the
plug
from
the
socket
for
afew
minutes.
Eliminate
the’
cause
of
overheating
and
then
re-insert
the
plug.
Most
malfunctions
are
caused
by
a
very
minor
and
easily
solved
problem.
Before
contacting
your
nearest
authorised
Service
Centre
for
assistance,
consult
the
troubleshooting
chart
below.
Do
not
carry
out
any
repair
operations
other
than
those
listed,
especially
on
the
electrical
equipment
in
the
unit.
If
the
Service
Centre
is
called
out
to
perform
any
of
the
operations
listed,
the
cost.
will
be
charged
to
you,
even
during
the
guarantee
period.