EasyManua.ls Logo

AEG LT20 - Completing Charging and Disconnecting the Charger; Charging Phases

AEG LT20
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.aeg-automotive.com26
Completing charging and disconnecting the
charger
1. 
the charging process.
2. First, remove the plug from the 230V power
socket.
3. 

terminal.
4. 

CHARGING PHASES
The concept of the charging process is explained

Diagnosis


Voltage Function
0 V bis 1.5 V 
1.5 V bis 12 V Charging starts.
12 V bis 13 V Maintenance charging starts.
14.6 V 

>15 V 
Step 1: Condition check
-
lates the required
charging parameters.
8
2
V
A
3 4 5 6 7 9
1
Step 2: Desulphation (rescue)
The charger can rescue most drained batteries
with voltages up to a minimum of 1.5 ±0.5 V.

start charging if the voltage is below 1.5 ± 0.5 V.
At a voltage range of 1.5 ± 0.5 V to 10.5 ± 0.5 V
the charger will initiate pulse charging.
If the voltage rises above 10.5 ± 0.5 V, the charger

charging mode, which will charge faster and more

Step 3: Precharging


Step 4: Soft start

current.
Step 5: Base charge with a constant current

consistent current.
Step 6: Base charge with a constant voltage


Step 7: Analysis

process will stop.
Step 8: Equalisation charge

within 2 minutes, another charging process will

Step 9: Maintenance charging



possible charging level.

Table of Contents