www.aeg-automotive.com26
Completing charging and disconnecting the
charger
1.
the charging process.
2. First, remove the plug from the 230V power
socket.
3.
terminal.
4.
CHARGING PHASES
The concept of the charging process is explained
Diagnosis
Voltage Function
0 V bis 1.5 V
1.5 V bis 12 V Charging starts.
12 V bis 13 V Maintenance charging starts.
14.6 V
>15 V
Step 1: Condition check
-
lates the required
charging parameters.
8
2
V
A
3 4 5 6 7 9
1
Step 2: Desulphation (rescue)
The charger can rescue most drained batteries
with voltages up to a minimum of 1.5 ±0.5 V.
start charging if the voltage is below 1.5 ± 0.5 V.
At a voltage range of 1.5 ± 0.5 V to 10.5 ± 0.5 V
the charger will initiate pulse charging.
If the voltage rises above 10.5 ± 0.5 V, the charger
charging mode, which will charge faster and more
Step 3: Precharging
Step 4: Soft start
current.
Step 5: Base charge with a constant current
consistent current.
Step 6: Base charge with a constant voltage
Step 7: Analysis
process will stop.
Step 8: Equalisation charge
within 2 minutes, another charging process will
Step 9: Maintenance charging
possible charging level.