2. INSTALLATION
495/595
D
371
H
Min.
850
2.1 Safe use of the
appliance
If tting the microwave in position B or C:
• The cupboard must be a minimum of
500 mm (E) above the worktop and
must not be installed directly above a
hob.
• This appliance has been tested and
approved for use near domestic gas,
electric and induction hobs only.
• Sucient space between hob and
microwave should be allowed to
prevent overheating of microwave
oven, surrounding cupboard and
accessories.
• Do not operate the hob without pans
when the microwave oven is operating.
• Care should be taken when attending
to the microwave oven while the hob is
on.
The microwave can be tted in position
A, B, C or D:
A
B
E
C
D
Conventional oven
Position
Niche size
W D H
A 562 x 550 x 360
B+C 462 x 300 x 350
462 x 300 x 360
562 x 300 x 350
562 x 300 x 360
D 462 x 500 x 350
462 x 500 x 360
562 x 500 x 350
562 x 500 x 360
Measurements in (mm)
3 - AEG_EN230_CS_BASE_AL28UICTO_SAFETYMAY19.indd 583 - AEG_EN230_CS_BASE_AL28UICTO_SAFETYMAY19.indd 58 06/04/2023 07:50:3906/04/2023 07:50:39