AEG WM 18 - End Charging Process

AEG WM 18
86 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
27
24 V
Once the battery has reached a voltage between 28.2 V and 28.7 V the battery is
fully charged. As soon as the voltage drops to 26.7 V maintenance charging will
start.
End charging process
1. Unplug from the AC outlet.
2. Disconnect the charging clamp (black) from the vehicle’s body, in exceptions
from the negative battery terminal (marked N or -).
3. Disconnect the positive charging clamp (red) from the positive battery terminal
(marked P or +).
Voltage “V”
maintenance charge
27.2
28.7
26.5
24
21
5.4 - 6A
4.3 - 5.2A
Shop charging device WM18 - 24 V
3.2 - 4.1A
1.8 - 2.6A
<1A
26.7(v)
27.5 - 28.7(v)
26.7 - 27.4(v)
25.5- 26.4(v)
21- 24.5(v)
Time "t"
Charging current “A”