The document describes a range of AEG angle grinders, specifically the WSL 180, WS 180 S, WSL 230, WSLB 230, WSLB 230 X, WSA 230 S, and WSB 230 S models. These are powerful tools designed for grinding and cutting various materials such as metal, stone, and other similar substances.
The AEG angle grinders are primarily used for abrasive tasks, including grinding, cutting, and brushing. They operate by rotating an abrasive disc or brush at high speeds. The design allows for both rough grinding and fine finishing, depending on the accessory used. The tools are equipped with safety features to ensure user protection during operation. Some models feature a "DEADMAN" switch, which requires continuous pressure to operate, stopping the tool immediately if the switch is released. This enhances safety by preventing uncontrolled operation. The tools are designed for robust use in professional and demanding environments.
The manual provides a table of technical specifications for the different models:
| Specification | WSL 180 | WS 180 S | WSL 230 | WSLB 230 | WSLB 230 X | WSA 230 S | WSB 230 S |
|---|---|---|---|---|---|---|---|
| Nominal power output (W) | 2000 | 2300 | 2000 | 2000 | 2300 | 2300 | 2300 |
| Rated output (W) | 1200 | 1400 | 1200 | 1200 | 1400 | 1400 | 1400 |
| No-load speed (min⁻¹) | 8500 | 8500 | 6600 | 6600 | 6600 | 6600 | 6600 |
| Max. grinding disc diameter (mm) | 180 | 180 | 230 | 230 | 230 | 230 | 230 |
| Spindle thread | M 14 | M 14 | M 14 | M 14 | M 14 | M 14 | M 14 |
| Weight without cable (kg) | 5.2 | 5.5 | 5.4 | 5.4 | 5.7 | 5.7 | 5.7 |
| Typical A-weighted vibration value in hand-arm area (m/s²) | 4.1 | 4.3 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 |
| Sound pressure level (dB (A)) | 92 | 95 | 92 | 92 | 95 | 95 | 95 |
| Sound power level (dB (A)) | 105 | 108 | 105 | 105 | 108 | 108 | 108 |
All values are measured according to EN 50 144. The tools are designed for operation with specific voltage requirements, with some models having variations for 110V.
Safety First: The manual emphasizes safety instructions, including the use of appropriate personal protective equipment such as safety goggles, ear protection, and sturdy non-slip shoes. It warns against using the machine without the protective guard and advises against modifying the tool. Always disconnect the plug from the socket before carrying out any work on the machine.
Starting and Stopping: For models with a standard switch, the tool is started by pressing the switch and locked for continuous operation. To stop, the switch is pressed again. For "DEADMAN" models, the tool starts when the switch is pressed and held, and stops immediately when released. This provides an added layer of safety.
Accessory Installation: The manual provides detailed visual instructions for mounting and dismounting various accessories, including grinding discs, cutting discs, and wire brushes.
Guard Adjustment: The protective guard is adjustable and can be rotated to different positions to suit the working angle and protect the user from sparks and debris. The guard is typically secured with a lever or screw mechanism, allowing for quick adjustments without tools.
Working Angle: For optimal grinding results and safety, the manual recommends maintaining a grinding angle of approximately 30° between the disc and the workpiece. It explicitly warns against using the side of the grinding disc for cutting, as this can lead to dangerous kickbacks or disc breakage.
Special Applications: The manual illustrates the use of a cutting guide accessory for precise cutting operations. This guide helps maintain a consistent depth and straight line during cutting.
General Maintenance: The ventilation slots of the machine must be kept clear at all times to prevent overheating. Regular cleaning of the tool is essential to ensure its longevity and safe operation. Dust and splinters must not be allowed to accumulate inside the machine.
Carbon Brush Replacement: The manual includes instructions for replacing the carbon brushes, which are critical components for the motor's operation.
The manual advises that if the carbon brushes are worn down to a minimum length (indicated by an automatic stop or reduced power), they should be replaced. It is recommended to replace both brushes simultaneously to ensure even wear and optimal performance.
Service and Repair: The document states that only original AEG accessories and spare parts should be used. For repairs, it is recommended to contact an authorized AEG service agent. The manual provides contact information for AEG Elektrowerkzeuge in Winnenden, Germany, for service inquiries and ordering spare parts.
Automatic Stop Feature: Some models are equipped with an automatic stop feature, which activates when the carbon brushes are worn out, preventing damage to the motor. When this occurs, the tool will stop, indicating that the brushes need replacement. This is a crucial maintenance indicator.
The CE declaration of conformity is included, affirming that the products meet the essential health and safety requirements of relevant European directives and standards.