2014/35/ECLowVoltageDirective(LVD)
2014/30/ECElectromagneticCompatibility(EMC),
inconformitywiththefollowingstandards:
ElectricalSafety:EN60335-1(2012)+A11+A13;EN60335-2-80(2003)+A1+A2.
ElectromagneticCompatibility:EN55014-1(2017);EN55014-2(2015);EN61000-3-
2(2014);EN61000-3-3(2013).
STANDARD CONFORMITY
Operation:connectedaccordingtothediagraminfig.13B,afterthelightisswitched
on,thefanactivateswithadelayofmax1.5seconds.Afterthelightisswitchedoff,the
fan continues to function for a pre-set period of time.
WITH HUMIDISTAT & TIMER
Thefanisequippedwithahumiditydetector,whosethresholdisadjustablefrom50%
to95%RelativeHumidity,andwithatimerwhichisadjustablefromaprox.1minuteto
25minutesviacorrespondingtrimmer(fig.14D).
TurnthetrimmerHYcompletelyclockwiseandthehumidistatfunctionisdeactivated.
Automatichumidistatoperation:connectedaccordingtothediagraminfig.13D,when
thepercentageofRelativeHumidityexceedsthepre-setinterventionthreshold,the
fanstartsupautomatically.WhenthepercentageofRelativeHumiditygoesbelowthe
threshold,thefancontinuestofunctionforapre-setperiodoftime.
Operationwithswitchconnection:connectedaccordingtothediagraminfig.13D,
afterthelightisswitchedon,thefanactivateswithadelayofaprox.1.5seconds.After
itisswitchedoff,thefancontinuestofunctionforapre-setperiodoftime.
Operationviapullcordswitch(HTPCversion):connectedaccordingtothediagramin
fig.14C.Byswitchingon,thefanactivateswithadelayofaprox.1.5seconds.After
switchingoff,thefancontinuestofunctionforapre-setperiodoftime.
Attention: When the relative humidity level is higher than the pre-set threshold,
automaticoperationwithhumidistathaspriorityovermanualoperation,orratherthe
fancannotbestoppedviaswitch.