ULTRASONIC FLOW METER
AFLOWT UF
(with cut-in converters)
VERSION UF-5xx d
INSTALLATION MANUAL
ISO 9001:2015
Question and Answer IconNeed help?

Do you have a question about the AFLOWT UF Series and is the answer not in the manual?

AFLOWT UF Series Specifications

General IconGeneral
TypeUltrasonic Flow Meter
Output4-20mA, Pulse, Relay
CommunicationRS485, Modbus
Resolution0.001 m/s
Temperature Range-40°C to 150°C (depending on transducer type)
Protection GradeIP65
Operating Temperature-20°C to 60°C
Storage Temperature-40°C to +70°C
DisplayLCD
DimensionsVaries by model
WeightVaries by model

Summary

Safety Instructions

Qualified Personnel for Flowmeter Operations

Specifies required qualifications for personnel performing mounting and dismounting.

Identification of Operational Hazards

Lists potential operational hazards including electrical voltage, pressure, and temperature.

Pre-Work Voltage Verification

Emphasizes verifying the absence of dangerous voltage on the pipeline section before commencing work.

Prohibited Actions During Operations

Details actions strictly forbidden during mounting, start-up, commissioning, and dismounting.

CS Module Protective Earthing

Outlines the procedure for connecting the CS module to the protective earthing trunk line.

Mounting Preparation

On-Site Mounting Conditions

Lists essential conditions that must be met for on-site flowmeter installation.

Transport and Environmental Acclimatization

Provides guidelines for transporting the flowmeter and allowing it to acclimatize to the environment.

Mounting Requirements

Primary Converter Mounting

Primary Converter Mounting

General Primary Converter Requirements

Specifies general conditions for mounting the Primary Converter, including liquid filling and turbulence.

Pipeline-CP Diameter Matching

Defines acceptable diameter differences between the pipeline and the CP at connection points.

PEA Cross-Sectional Placement

Advises against installing the CP with PEAs positioned at the extreme top or bottom of the pipeline's cross-section.

Single-Beam Sounding PEA Placement

Details the correct angular and positional placement of PEA pairs for single-beam sounding.

Two-Beam Sounding PEA Placement

Explains the required placement of PEA pairs for two-beam scanning along horizontal chords.

Four-Beam Scanning PEA Placement

Describes the positioning of PEA pairs for four-beam scanning along horizontal chords.

Straight Pipe Run Lengths

Straight Pipe Run Lengths

Optimal Straight Pipe Run Lengths

Specifies the minimum straight pipe run lengths required upstream and downstream of PEAs for optimal operation.

Straightening Vane Impact on Pipe Run Lengths

Notes that installing a straightening vane can reduce the required length of straight pipe runs.

U-Elbow CP Straight Pipe Run Rules

States that specific straight pipe run length requirements are not defined for U-elbow type Primary Converters.

Secondary Converter Placement Requirements

Outlines the conditions and considerations for placing the Secondary Measuring Converter (CS).

Flowmeter Mounting

Primary Converter Installation

Primary Converter Installation

Required Fittings for Primary Converter Installation

Lists the necessary fittings for installing the Primary Converter (CP) into the pipeline.

Securing Pipeline Sections During Installation

Advises securing pipeline sections to prevent movement after cutting for CP mounting.

Assembly of Flanged Primary Converter

Describes the process of assembling the flanged CP and companion flanges into a single unit.

Welding the Primary Converter Assembly

Details the procedure for cutting the pipeline and welding the assembled CP into place.

Pipeline Welding Compliance and Alignment

Covers welding the assembly to the pipeline according to local regulations and ensuring proper alignment.

Secondary Measuring Converter Installation

Explains the procedure for mounting the Secondary Measuring Converter (CS).

Flowmeter Wiring Procedures

Flowmeter Wiring Procedures

PEA to CS Connection Correspondence

Guides on connecting PEAs to CS, ensuring channel characteristic correspondence.

Cable Laying Procedures

Details laying of power, CS-PEA, and CS-external device cables according to operating conditions.

Cable Fixing and Separation

Provides guidelines for fixing communication and network cables, including separation and protection.

Cable Coiling Restriction

Advises against coiling excess cables to maintain order and prevent damage.

Cable End Preparation

Instructs on preparing cable ends by stripping insulation by 5 mm prior to connection.

CS-PEA Cable Heat Protection

Warns about CS-PEA cable contact with heated pipelines and suggests thermal insulation.

RS-Output Connection

Explains connecting the flowmeter's RS-output to external devices using standard cables.

Protective Grounding Requirements

Discusses the necessity of protective grounding based on power supply and environmental conditions.

Start-Up Procedure

Pre-Start-up Parameter Check

Instructs to verify flowmeter parameters against passport data before initiating start-up.

PEA Parameter Entry Reference

Directs users to the Operation Manual for PEA parameter entry procedures.

Measurement Result Processing Reference

Directs users to the Operation Manual for adjusting measurement result processing.

External Device Connection and Adjustment

Guides on connecting external devices and adjusting outputs as per Operation Manual instructions.

Date and Time Setting

Details checking and setting the current date and time for the flowmeter.

Switching to Operation Mode

Explains switching the device to OPERATION mode by removing a specific jumper.

Performance Factors

Notes that mounting and operating conditions are based on typical factors affecting performance.

Dismounting

Flowmeter Dismounting Steps

Lists the essential steps for dismounting the flowmeter, including powering off and draining.

Pre-Dispatch Cleaning

Instructs on cleaning the flowmeter and PEAs before dispatch for calibration or repair.