Fig.D.2. Design of type B flow straightening vane.
3. Hole marking in straightening vanes is shown in Table D.1.
Table D.1. Coordinates of the holes in straightening vanes of A and B type
(D – pipeline internal diameter)
4. The straightening vane is installed in the pipeline at a distance of 12
pipeline’s DN from the last source of hydraulic resistance with respect
to the flow direction. When installing the straightening vane, the length
of a straight run before the PEA is determined as the distance from the
source of hydraulic resistance to the PEA.