CONTENTS:
Functional description ................ 2
Component parts ....................... 3
Spare parts ................................. 5
Safety regulations ....................... 6
Checklist ..................................... 7
Installation .................................. 8
Commissioning ......................... 11
Operation .................................. 14
Maintenance ............................. 15
Troubleshooting ....................... 16
Technical data .......................... 18
Retain these instructions for
future use.
Edition 1.3 - 18-11-22
OSA 3
Level alarm for oil separator

Questions and Answers

  • D
    Donna GrayAug 15, 2025
    What to do if the "Sludge alarm act." alarm appears on AFRISO OSA 3 Measuring Instruments?
    • S
      Susan HarrisAug 15, 2025
      If the "Sludge alarm act." alarm appears, it means the sludge level has reached a set alarm level. In this case, separator emptying should be ordered.
  • J
    Julie ZavalaAug 18, 2025
    What to do if "High level alarm act." alarm appears in AFRISO OSA 3 Measuring Instruments?
    • B
      beardjayAug 18, 2025
      If the "High level alarm act." alarm appears, there may be a blockage at the outlet to the separator. Clear the blockage or find out what is causing it.
  • W
    William MccoyAug 21, 2025
    What to do if "Sensor err on input 1 (level)" alarm appears in AFRISO OSA 3 Measuring Instruments?
    • A
      angelaroyAug 21, 2025
      If the "Sensor err on input 1 (level)" alarm appears, there may be an error in the sensor circuit to the sensor, such as a cable failure or short-circuit. To resolve this, measure the voltage at the sensor.
  • K
    kellyandrewAug 25, 2025
    What to do if "Sensor err on input 2 (high level)" alarm appears in AFRISO OSA 3?
    • N
      Nathan NicholsAug 26, 2025
      If the "Sensor err on input 2 (high level)" alarm appears, there may be an error in the sensor circuit to the sensor, such as a cable failure or short-circuit. To resolve this, measure the voltage at the sensor.
  • T
    tbennettAug 28, 2025
    What to do if "Sensor err on input 3 (sludge)" alarm appears in AFRISO OSA 3 Measuring Instruments?
    • J
      julie90Aug 28, 2025
      If the "Sensor err on input 3 (sludge)" alarm appears, there may be an error in the sensor circuit to the sensor, such as a cable failure or short-circuit. To resolve this, measure the voltage at the sensor.
  • K
    Kristina DelgadoAug 31, 2025
    What to do if "Level alarm act." alarm appears in AFRISO Measuring Instruments?
    • V
      Vincent BakerAug 31, 2025
      If the "Level alarm act." alarm appears, you should order emptying.
  • L
    logan40Sep 4, 2025
    What to do if the sensor is not connected or there is a cable failure in AFRISO Measuring Instruments?
    • P
      powellanthonySep 4, 2025
      If the sensor is not connected or there is a cable failure, connect the sensor or troubleshoot the cable.
  • N
    Nicole NunezSep 7, 2025
    What to do if the sensor is connected incorrectly in AFRISO OSA 3 Measuring Instruments?
    • L
      Lauren RichardsonSep 7, 2025
      If the sensor is connected incorrectly, check the polarisation.
  • R
    Renee Spears DDSSep 12, 2025
    What to do if the sensor circuit is short-circuited in AFRISO OSA 3?
    • C
      casey69Sep 12, 2025
      If the sensor circuit is short-circuited, check the sensor circuit.

Summary

Functional Description

Component Parts

Options

Spare Parts

Safety Regulations

Checklist

Before Installation

Essential checks for commencing the electrical installation of the OSA 3 unit.

After Installation

Final checks for correct installation and connection of the OSA 3 unit after setup.

Installation

Wiring with Multi-Core Cables

Details wiring procedures for multi-core cables for the OSA 3 system.

Terminals Overview

Explains the function of terminals K1, K2, K3, K4 on the OSA 3 central unit.

Wiring with Individual Cables

Outlines procedures for wiring the OSA 3 using individual cables and junction boxes.

Assembly

Sensor Installation Guidelines

Provides specific guidance on fitting level, damming, and sludge sensors for optimal performance.

Commissioning

Operation and Setup

Covers initial operation, button functions, automatic setup, and setting date/time for the OSA 3.

Sensor Function Control

Scanning and Testing Sensors

Details the procedure for scanning and testing sensors to ensure proper function.

Testing Damming and Sludge Sensors

Explains how to test the damming (R6-S) and sludge (ES8) sensors.

Operation

Normal Operation Display

Explains the display status during normal operation (STATUS OK).

Alarm Indications and Actions

Details how different alarms are indicated and the recommended actions.

Maintenance

Sensor Cleaning and Testing

Covers periodic cleaning of sensors and testing requirements as per standards.

Programming Functions

Details access and use of programming functions like Date/Time, Inputs, Relay settings, and Language.

Troubleshooting

Alarm Display Issues

Provides a guide to common alarm messages, their checks, and potential causes/actions.

Sensor Voltage Diagnostics

Measurement and Troubleshooting Table

Explains sensor voltage measurements and provides a table for checking sensor status and actions.

Technical Data

Component Specifications

Lists technical specifications for the OSA 3 central unit and its sensors.

Definitions

Provides definitions for key terms used in the manual.

EU Declaration of Conformity

Notes

AFRISO OSA 3 Specifications

General IconGeneral
Service life of the batteryUp to 10 years
HousingPlastic
ColourWhite
Power supply3 V lithium battery
Alarm volume85 dB (A) at a distance of 3 m
Operating temperature0 °C...+55 °C
Storage temperature-20 °C...+60 °C
Air humidity15 to 95 % RH (non-condensing)
Diameter100 mm
ApprovalsEN 14604

Related product manuals