48
(1) On last engine operation, drain the lubricating oil in the engine and oil filter after the engine has stopped and
cooled down to warm state. It is not necessary to drain coolant because it is anti-rust. Add qualified anti-rust oil
(dewatered CF 15W-40 oil) into the engine, start the engine to idle for 1-1.5 minutes and stop it, then drain the
anti-rust oil.
(2) Refer to Article 1, 2, 3, 4 and 5 in Section 6.1.1 Short Time Storage for cleaning, preventing rust and other
requirements. And put a tag which reads “The engine does not contain oil and do not use it.”
6.2.2 During the storage
Refer to 6.1.2 for storage.
6.2.3 After storage
When putting the engine into use, remove the fuel pump and send it to the authorized service provider for adjustment.
Remove the engine cover and all port covers. Install the fuel pump and prime the fuel system. Connect battery and
install the belt. Fill the engine and oil filter with clean lubricating oil and add proper amount of clean lubricating oil into
turbocharger from its oil inlet. Check oil and coolant levels, and crank the engine three to five circles with barring tool.
Then follow the starting procedures in Section 3.4 to start the engine. If the engine is stored for over 2 years, its
coolant should be changed and its cooling system should be cleaned.