ESG Family Signal Generators Hardkey and Softkey Reference
Utility
User’s Guide 4-127
Options Info
Press this softkey to retrieve information regarding the options
installed in the instrument. This information may include any of the
following information:
Option number: the alpha or numeric designation of the installed
option, for instance: option UN8, UNB or 300.
Hardware version: the letter designation of the installed hardware
for the listed option number, for instance: UN8 or UN9
version C,
or UN7
version A.
DSP version: the name of the DSP (digital signal processor)
firmware version for the installed option card.
Softkey Location:
Utility > Instrument Info/Help Mode > Options Info
Page Down
Press this softkey to move down in the displayed catalog of files one
page at a time.
Softkey Location:
Utility > Memory Catalog > Page Down or Utility >
Memory Catalog > Goto Row > Page Down
Page Up
Press this softkey to move up in the displayed catalog of files one page
at a time.
Softkey Location:
Utility > Memory Catalog > Page Up or Utility >
Memory Catalog > Goto Row > Page Up
Pattern Trigger In Polarity Neg Pos (Option UN8)
This softkey in the Signal Polarity Setup menu is used to configure the
polarity of the TTL signal at the PATTERN TRIG IN connector that
triggers an event. Pos refers to the rising edge, while Neg refers to the
falling edge.
Default Value: Pos
Softkey Location:
Utility > Instrument Adjustments > Signal Polarity Setup >
Trigger In Polarity Neg Pos
PN9 Mode Preset Normal Quick (Option UN8)
This softkey sets the preset value for the PN9 mode. The choices are
Normal and Quick. PN9 mode only applies to personalities that require
software PRBS.
Default Value: Normal
Softkey Location:
Utility > Power On/Preset > PN9 Mode Preset Normal Quick

Other manuals for Agilent Technologies E4422B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies E4422B and is the answer not in the manual?

Agilent Technologies E4422B Specifications

General IconGeneral
BrandAgilent Technologies
ModelE4422B
CategoryPortable Generator
LanguageEnglish

Related product manuals