11 Reliability
[Measurement Parameters]
Port1 current Iport1
Port3 current Iport3
Port4 current Iport4
[User Function]
Voltage between terminals of wiring device DeltaV=Vm1-Vm2
Resistance of wiring device R=Vport1/Iport2
[X-Y Graph]
X axis: Stress time Time (LOG)
Y1 axis: Resistance of wiring device R (LINEAR)
Y2 axis: Port1 current Iport1 (LINEAR)
Y3 axis: Port3 current Iport3 (LINEAR)
Y4 axis: Port4 current Iport4 (LINEAR)
Y5 axis: Voltage between terminals of wiring device DeltaV (LINEAR)
[List Display]
Stress time Time
Resistance of wiring device R
Port1 current Iport1
Port3 current Iport3
Port4 current Iport4
Voltage between terminals of wiring device DeltaV
[Test Output: X-Y Graph]
X axis: Accumulated stress time TimeList (LOG)
Y1 axis: Resistance of wiring device RList (LINEAR)
Y2 axis: Port1 current Iport1List (LINEAR)
Y3 axis: Port3 current Iport3List (LINEAR)
Y4 axis: Port4 current Iport4List (LINEAR)
Y5 axis: Difference from initial resistance DeltaRList (LINEAR)
[Test Output: List Display]
Accumulated stress time TimeList
Resistance of wiring device RList
Port1 current Iport1List
Port3 current Iport3List
Port4 current Iport4List
Difference from initial resistance DeltaRList
[Test Output: Parameters]
Time to failure given by rate of resistance change R_FailureTime
Time to failure given by monitoring extrusion lines E_FailureTime
Agilent EasyEXPERT Application Library Reference, Edition 8
11-61