11 Reliability
[Test Parameters for IvSweep_ConstId]
MeasGate: SMU connected to the basic characteristics acquisition Gate terminal, primary sweep voltage
output
MeasDrain: SMU connected to the basic characteristics acquisition Drain terminal, constant voltage output
MeasSource: SMU connected to the basic characteristics acquisition Source terminal, constant voltage output
MeasSubs: SMU connected to the basic characteristics acquisition Substrate terminal, constant voltage output
Id@Vth: Drain current to decide the Vth, per unit area
VgStart1: Sweep start voltage for Gate terminal
VgStop1: Sweep stop voltage for Gate terminal
VgStep1: Sweep step voltage for Gate terminal
Vd1: Drain terminal voltage
[Test Parameters for IvSweep_gmmax]
MeasGate: SMU connected to the basic characteristics acquisition Gate terminal, primary sweep voltage
output
MeasDrain: SMU connected to the basic characteristics acquisition Drain terminal, constant voltage output
MeasSource: SMU connected to the basic characteristics acquisition Source terminal, constant voltage output
MeasSubs: SMU connected to the basic characteristics acquisition Substrate terminal, constant voltage output
VgStart2: Sweep start voltage for Gate terminal
VgStop2: Sweep stop voltage for Gate terminal
VgStep2: Sweep step voltage for Gate terminal
Vd2: Drain voltage
[Test Parameters for Sampling_Ids]
MeasGate: SMU connected to the basic characteristics acquisition Gate terminal, primary sweep voltage
output
MeasDrain: SMU connected to the basic characteristics acquisition Drain terminal, constant voltage output
MeasSource: SMU connected to the basic characteristics acquisition Source terminal, constant voltage output
MeasSubs: SMU connected to the basic characteristics acquisition Substrate terminal, constant voltage output
Vg3: Gate terminal voltage
Vd3: Drain terminal voltage
[Extended Test Parameters]
[Extended Test Parameters for IvSweep_ConstId]
HoldTime: Hold time
DelayTime: Delay time
Vsubs: Substrate terminal voltage
Vs: Source terminal voltage
IgLimit: Gate current compliance of devices
IdLimit: Drain current compliance of devices
IsubsLimit: Substrate current compliance
DrainMinRng1: Minimum range for drain current measurement on device 1
DrainMinRng2: Minimum range for drain current measurement on device 2
DrainMinRng3: Minimum range for drain current measurement on device 3
[Extended Test Parameters for IvSweep_gmmax]
HoldTime: Hold time
DelayTime: Delay time
Vsubs: Substrate terminal voltage
Vs: Source terminal voltage
IgLimit: Gate current compliance of devices
IdLimit: Drain current compliance of devices
IsubsLimit: Substrate current compliance
gmMax_Min: Minimum gmMax value for graph scale
Agilent EasyEXPERT Application Library Reference, Edition 8