78 Agilent InfiniiVision 3000 X-Series Oscilloscopes User's Guide
4 Math Waveforms
See Also "To perform transforms or filters on an arithmetic operation" on
page 73
"Units for Math Waveforms" on page 74
Integrate
dt (integrate) calculates the integral of the selected source. You can use
integrate to calculate the energy of a pulse in volt- seconds or measure the
area under a waveform.
dt plots the integral of the source using the "Trapezoidal Rule". The
equation is:
Where:
I = integrated waveform.
Figure 7 Example of Differentiate Function
I
n
= c
o
t
i=0
n
y
i

Table of Contents