6.7 Inquiry Alarm Setting
Reply: Alarm Inputs Disabled or Alarm Inputs Enabled.
Tips: Alarm Inputs Disabled means disable the digital inputs, Alarm Inputs Enabled means Enable digital
inputs.
6.8 Setup allow all calling in numbers can access it
Tips: This command allows anybody calling the SIM number to access it.
Warning! With the above command you allow free access to anybody calling!
6.9 Setup only authorized number can access it (Default)
Tips: With the above command you allow only people that are in the authorized number list can
access the RTU5015. This is the standard and recommended option.
Inquiry this setting
Relpy: Allow all numbers can access it or Allow User Number can access it only.
6.10 Setup the relay close time
Tips: The time should be in 0~9.5seconds.
This command is useful in case you need to keep the relay closed (or button pressed) longer. The default
time is 0.5seconds (500 ms). You can change it with the GOT command. The relay closed time is twice as
the number you set, e.g.: if you set pwd#GOT19#, means the relay closed 19/2=9.5Seconds.
To check the value, you can use the command pwd#GOT? , the unit will reply the current value.
If you want to let the relay always closed until you call it next time, then you can set the time as 00, the
format is pwd#GOT00#, the relay will be always closed until next time call in. in this case, only the 1
st
, 2
nd
,
3rd authorized number can access it. The other authorized numbers can not access the unit. This is very
useful for remote switch on or switch off the electricity appliance or equipment or device for a long time.
6.11 Modify the digital input type
Modify the digital input type as NC; if the sensor you used with this unit is NC, then you should set the unit
as NC type.
Tips: when you set the digital inputs as NC, if you don’t use the input, please connect the digital inputs by
a wire to short it. Otherwise, it will alarm. E.g.: if you only use the input 2, then you should use a wire to
pwd#AL?
pwd#AA#
pwd#AU#
pwd#AC?#
pwd#GOTTime#
pwd#KEYNC#