The local Alarm will stop sounding but you will hear the other Alarms still sounding
in the distance.
End of Life (EOL) Check
Check the ‘replace by date’ label on all Ei3000MRF modules and attached Alarms.
If the date has been exceeded then the module should be replaced.
Identifying source of Alarm
Ei Electronics Carbon Monoxide Alarms and Smoke Alarms can be interconnected
via RadioLINK or SmartLINK so that one Alarm sensing danger will cause all the
other units to sound, enabling the alarm to be heard throughout the residence.
When a system alarms, check to see which unit has its red light flashing rapidly - this
it the source of the alarm.
If it is a Carbon Monoxide Alarm, ventilate the residence and follow the instructions
in the Carbon Monoxide Alarm manual.
If it is a Smoke Alarm, evacuate the residence and follow the instructions in the
Smoke Alarm manual.
For added convenience we recommend that an Ei450 Alarm Controller is used
with these systems. When there is an alarm, an icon on the Ei450 Alarm Controller
shows if it is a CO or Fire incident and can be remotely controlled accordingly.
16
Interconnected Carbon Monoxide
Alarms and Smoke Alarms