28 / 28
⚫ Whether the module glass is broken,
⚫ Whether the backsheet of the module is damaged or otherwise abnormal,
⚫ Whether the junction box is damaged or the cable is broken,
⚫ Whether the module is shaded by foreign matter or shadows,
⚫ Check whether the bolts fixing the module to the racking are loose or corroded and adjust or replace
them if necessary,
⚫ Check whether the modules are well-grounded.
9.3 Checks of connectors and cables
It is recommended to perform preventive examinations every six months, such as:
⚫ Whether the connectors are properly sealed and the cables are properly fastened,
⚫ Whether the sealant of the junction box is cracked.
9.4 AIKO Technical Support
In order to request Technical Support:
⚫ Collect evidences of the issue as (a) photos and (b) measurements.
⚫ Be prepared to show the purchase invoice and module serial number.
⚫ Contact your Installer.