Main Menu Group Constant LCD Display Range Unit
Factory
Setting
Remark Page
Programming
D
D-03
When D-01= Time
00~23 Hr
00~59 Min
1 Min 0 5-11
When D-01=Battery SOC 0~100 1% 0 5-11
D-04 Aux RY1 MIN. ON time
0~23 Hr,
0~59Min
1 Min 0 5-12
E
Auxiliary Relay 2
E-01 Set Aux Relay 2 Mode
OFF, ON,
Solar Voltage,
Output Volts,
Battery Volts,
OUT Current,
BATT Current,
Temperature
Battery Temp.
Time,
Battery SOC,
Output Volts
─
OFF 5-12
E-02
Aux RY2 ON Condition See Below
See
Below
See
Below
5-12
When E-01= Solar Voltage
0~150/0~250 0.1V 0 5-12
When E-01=Output Volts 0~64 0.1V 0 5-12
When E-01=Battery Volts
0~64 0.1V 0 5-12
When E-01=OUT Current
0~80 1A 0 5-12
When E-01=BATT Current
-500~500 1A 0 5-12
When E-01=Temperature
-20~100 1
℃
0 5-12
When E-01=Battery Temp.
-20~100 1
℃
0 5-12
When E-01= Time
00~23 Hr
00~59 Min
1 Min 0 5-12
When E-01=Battery SOC
0~100 1% 0 5-12
E-03
AuxRY2 OFF Condition See Below
See
Below
See
Below
5-12
When E-01= Solar Voltage
0~150/0~250 0.1V 0 5-12
When E-01=Output Volts 0~64 0.1V 0 5-12
When E-01=Battery Volts
0~64 0.1V 0 5-12