00.00 Hr, it means that the PV array is not sufficiently sized to keep up with the load. Use a
generator for additional battery charging, reduce loads, or expand the PV array to ensure that the
batteries are fully recharged. For maximum service life batteries should be fully recharged at least
once every five to ten days.
G-03: Set Day LOG# (1-90)
Use G-03 to set the Day Log number to display the energy harvested from the PV array (shown in
G-04 and G-05) by AIMS MPPT+ over a period of time.
If it is selected as #2 it will display past power production since the last power cycle (or up to 90
days previous) along with yesterdays date.
Use UP and DOWN keys to select the date by one. The energy harvested on the date shown is
displayed in G-04.
G-04: Day LOG# :kWHr
This screen displays how much the solar energy has harvested in kWHr and AHr according to the
selected day shown in G-03.
G-05: Day LOG# @FLOAT
This screen displays how much time the charger was in Float mode according to the selected day
shown in G-03.
G-07: Average Last Days
xxxxx kWHr xxxx AHr
This screen shows the average power produced over the past cumulative days as both in kWHr
and AHr.
G-08: Average Last Days
FLOAT xx : xx
This screen displays how much average time the charger was in Float mode in the past cumulative
days, shown in Hour: Minute.
G-09: Clear Energy Harvest
Use Constant G-09 to clear Today’s Data or all the Logged Data.
Press ENTER key and use UP and DOWN keys to select between Today’s Data and Logged Data
and then press ENTER key again to clear the selected data.