O-03: Set Date
This is the same display as in the initialization setup of battery.
Press ENTER key to start to edit the MM/DD/YY and press UP and DOWN key to increment or
decrement the values.
O-04: Model Number
The model number of the unit is displayed.
O-05: Turn OFF Backlight T
Use Constant O-05 to set the operation of the LCD backlight. Since the backlight consumes a fair
amount of quiescent current, it is recommended that the on time be as short as possible.
Press ENTER key to enter the setting and press UP and DOWN key to turn off from NEVER
(always on) or 1 to 10 minutes in 1 minute increments.
Note: When the backlight turns off, pressing any key will turn it back to U-00 display screen.
O-06: Fan Test
Use Constant O-06 to test if the fan can be forced to be ON or OFF.
When FAN ON is selected, the fan test is conducted as the O-06 screen remains. Once the screen
leaves O-06, it will stop the test running.
O-07: Software Version
The software version displayed is important and useful when contacting Technical Support.
O-08: ***Bootloader***
This is the Bootloader initiation display. It is only used to update the firmware.
*** Main Menu***
Data Log
G-01: EnergyHarvest Today 1
This screen displays how much the solar energy has harvested “Today” in kWHr and AHr unit.
G-02: EnergyHarvest Today 2
This screen displays how much time the charger has been in Float mode “Today”.
It is valuable to know that the charger enters Float mode because this is a clear indication that the
batteries have been fully recharged. If the value displayed in “G-02=FLOAT ” is consistently