Setting Usage
Standalone
Used when there is only one AIMS MPPT+ with a Remote
Display connected.
Master
Used to assign the network master (this is the AIMS MPPT+
that connects to the shunt).
Slave
Assigns up to 15 additional AIMS MPPT+ slave units.
The first AIMS MPPT+ is assigned as master and the rest of
units in network are slaves. The network address will be
assigned to each slave unit in F-02.
F-02: Parallel Addr
An AIMS MPPT+ assigned as Master or Standalone is always addressed 01 automatically so the
address assignment in F-02 is only available for the slave units.
The maximum slave address number is 16 and the factory setting is 2.
Group O
Operator
O-01: Set CLOCK Mode
This is the same display as in the initialization setup of battery.
Use Constant O-01 to change and select the hour format displayed between 12 Hour and 24 Hour.
Factory setting is 12 Hour Format.
When 12 Hour is selected, AM and PM indication will be shown in O-02.
O-02: Set Time
This is the same display as in the initialization setup of battery.
When 12 Hour format is selected in O-01, AM and PM indication will be shown.
Press ENTER to start to edit the Hour:Minute: Second number and press UP and DOWN key to
increment or decrement the values.