EasyManua.ls Logo

Aiphone GF-MK User Manual

Aiphone GF-MK
8 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
I
SECURITY GUARD STATION
1
INSTALLATION
&
OPERATION MANUAL
PRECAUTIONS
A
WARNING
(Negligence could
result
in death or serious
injury
to
people.)
1. Do not open the unit case.
8
2. Do not dismantle or alter the unit. Fire or electric shock
could results.
3. Keep the unit away from water or any other liquid.
Fire or electric shock could result.
4.
Do not put any metal into the unit through openings.
Fire, electric shock or unit trouble could result.
8
A
CAUTION
(Negligence
could
result
in
injury
to
people
or damage
to
property)
1. Mount the unit on wall in a convenient location, but not
where it could be bumped or jarredhjury could result.
2. Do not install or make any wire terminations while power
supply is turned on. Unit trouble could result.
3. Before turning on power supply, make sure wires are not
crossed or shorted. Unit trouble could result.
4. Do not manually hold down hook switch to verify chime
volume. It sounds very loud near your ears and can
cause your hearing damage.
5.
Do not press hard or put high impact on LCD.
If
glass
cover is broken, you may be injured, and never touch the
liquid inside panel, as it can cause an inflammation on
your skin.
If
the liquid adheres to any part of your body,
mouth or eyes, immediately gargle or cleanse with clear
water for at least
15
minutes and consult your doctor.
8
8
8
8
6.
Do not install the unit in any of the following locations, as
it
may cause the system to malfunction;
-
High or extreme cold temperature area: under direct sunlight,
near equipment that varies in temperature, in front of air
conditioner, inside a refrigerated area, etc.
-
Places subject to moisture or humidity extremes.
-
Places subject to environmental conditions,
-
Places subject to constant vibration or impact.
8
-
Places subject to steam
or
smoke, such as near heating
8
such as oil, dust, chemicals, salt, etc.
8
8
appliances, cooking surface, etc.
GENERAL PRECAUTIONS
1. All the units, except the Entrance Station, is designed for
indoor use only. Do not install them outdoors.
2. The system is not operable during a power failure.
3. In areas where broadcasting station antennas are close
by, intercom system may be affected by radio frequency
interference.
4.
Keep all wiring at least 30cm
(1")
away from AC 100-240V
wiring, fluorescent lighting, or dimmer switches.
Otherwise, cross AC wiring at a 90" angle.
General Prohibitions Prohibitions to subject
Prohibitions
to
dismantle the unit
the unit to water
NAMES AND FUNCTIONS
1. Handset
PACKAGE CONTENTS
Mounting bracket
=
Packet of screws
Connecting cable
*
INSTALLATION
&
OPERATION
2. LCD display
3.
%
CANCEL
(or decide
&
back)
1
2
4.
A
SCROLL backward
or move cursor to left
3
6
5.
SCROLL forward
or move cursor to right
6.
0
CALL
(or decide
&
next)
4
7
7.
Digital keypad
(1
-
0,
*,
#)
5
*
10
11
12
10. DOOR RELEASE button
11. Off-hook warning LED
13
12. Call tone sounder
14 Entrance Station, press to 13. Call tone volume control
14. PC socket
~henenfering/e~e~; A-Z,
0
=
[,
] [
-1
[.
]
[
/]
[
]
Functions
:
*
Dialing Room
#
*
Name search with
@
key and calling
8.
SERVICE button (Option)
9. LIGHT button When communication with
turn on external light.
\-I
PROGRAMMING
METHODS
COMMUNICATION FUNCTIONS
Programming by PC
-
It is possible to write or change resident names
-
Download Programming & Alteration Method
Calling
&
Communication
a. with Residential Stations.
-b
GO
to
p.4
from your PC, making data input. b. with Entrance Station.
-+
Go
to
p.5
c. with Security Guard Station.
-b
Go
to
P.6
from Aiphone's Web Site: d. PANIC call & Answer-back.
-b
GO
to
p.6
httix/iwww.aiDhone.com/
(*
Includes Line-off trouble alarm)
-
Cinnect your'PC with GF-MK in conjunction with
Programming by GF-MK
-
On LCD display, see a message "AIPHONE to
confirm system is in standby.
Prior to programming, it is suggested to have
your own ID code newly registered,
so
that any
other person cannot get into the system.
Firstly, enter program mode.
the connecting cable supplied with GF-MK.
-b
GotoP.2
-b
GotoP.8
*
In case your programmed ID code is forgotten,
Security Guard Stations
1
& 2
Entrance
b
-1-
l.
-A\
-
Residential Stations
==
6..
...........
"Y
.... .
____j
CALL
Question and Answer IconNeed help?

Do you have a question about the Aiphone GF-MK and is the answer not in the manual?

Aiphone GF-MK Specifications

Weight and Dimensions IconWeight and Dimensions
dimensions210 H x 215 W x 69 D (mm), 8-1/4" H x 8-1/2" W x 2-3/4" D
unit weight900g (1.98 lbs)

Summary

Safety and Precautions

General Safety Precautions

Covers critical safety warnings and cautions to prevent injury, death, or property damage during installation and operation.

General Precautions

Lists general advice on installation locations, environmental conditions, and potential interference.

System Components and Functions

Names and Functions Overview

Identifies and describes the physical components and buttons of the GF-MK station.

Programming Methods

Details methods for programming the system via PC or directly on the GF-MK unit.

Communication Functions

Outlines the communication capabilities, including calling residential and entrance stations, and panic calls.

System Programming Procedures

Entering Program Mode

Step-by-step guide to access the programming menu on the GF-MK.

Programming Menu Options

Guides for language selection, ID code changes, residence info, and timer settings.

Programming Residential Stations

Detailed steps for linking and programming residential stations to the Guard Station.

Station Communication Operations

Calling Residential Stations

Methods to call residential units by name, room number, or alphabetical search.

Receiving Calls from Residential Stations

How the GF-MK station receives and handles calls from residential units.

Entrance Station Communication

Procedures for receiving calls from and making calls to entrance stations, including door release.

Inter-Station Communication and Panic Calls

Instructions for communication between Guard Stations and handling panic calls.

Installation and Wiring

Mounting the GF-MK Station

Details on desk-top and wall-mounting configurations for the security guard station.

System Wiring Connections

Explains terminal block connections for integrating GF-MK with other Aiphone devices.

Technical Details and Support

Technical Precautions and Maintenance

Guidelines for operating temperature, cleaning, and switch settings.

Product Specifications

Lists physical dimensions, display capabilities, and unit weight of the GF-MK.

Product Warranty Information

Information regarding the warranty period and terms for Aiphone products.

Related product manuals