Air-Con ASREM4H4S18 - User Manual

Air-Con ASREM4H4S18
74 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
1
Service Manual

Questions and Answers

  • K
    Kelsey PorterAug 18, 2025
    What to do if there is a communication failure between the indoor unit and outdoor unit in my Air-Con Air Conditioner?
    • A
      Anna SchroederAug 18, 2025
      If the Air-Con Air Conditioner displays a communication failure between the indoor and outdoor units, check the following: * Ensure the communication cable is securely connected. * Verify the communication cable is not faulty. * Check the connection between the filter board and the outdoor control board, ensuring it is correct and secure. * Check the connection between the filter board and the terminal, ensuring it is correct and secure. * The indoor control board might be faulty. * The PFC board might be faulty. * The power board might be faulty. * The outdoor control board might be faulty.
  • A
    Aaron KellyAug 20, 2025
    What causes current overload protection in Air-Con Air Conditioner?
    • J
      James CarrilloAug 20, 2025
      If your Air-Con Air Conditioner is showing current overload protection, it might be due to: * Abnormal fan motor operation. * Dirty condenser and evaporator coils. * Abnormal air inlet or outlet conditions.
  • T
    Tony PowellAug 23, 2025
    Why does my Air-Con Air Conditioner show compressor exhaust temperature too high protection?
    • K
      Katherine WilsonAug 23, 2025
      If your Air-Con Air Conditioner is showing compressor exhaust temperature too high protection, it could be due to: * A faulty compressor exhaust temperature sensor. * Insufficient refrigerant in the unit.
  • P
    Pamela JonesAug 26, 2025
    What causes compressor shell temperature too high protection in Air-Con Air Conditioner?
    • S
      Stacy JonesAug 26, 2025
      If your Air-Con Air Conditioner is showing compressor shell temperature too high protection, it might be due to: * A loose connection of the compressor exhaust temperature sensor. * Insufficient refrigerant in the unit.
  • A
    Amy CampbellAug 28, 2025
    What to do if my Air-Con Air Conditioner shows anti-freeze or overload protection?
    • A
      Abigail BlakeAug 28, 2025
      If the Air-Con Air Conditioner is experiencing anti-freeze protection during cooling or overload protection during heating, consider the following: * Check if the indoor coil temperature sensor is loosely connected. * The indoor coil temperature sensor might be faulty. * The indoor control board might be faulty. * The refrigerant system might be abnormal.
  • H
    harrisbrendaAug 30, 2025
    What to do if the compressor drive is in trouble in my Air-Con Air Conditioner?
    • D
      Douglas WilsonAug 30, 2025
      If your Air-Con Air Conditioner's compressor drive is in trouble, possible causes include: * A faulty outdoor drive board. * A faulty compressor. * A faulty outdoor control board.
  • J
    jillwatsonSep 2, 2025
    Why is the outdoor fan motor locked on my Air-Con Air Conditioner?
    • S
      Stanley BakerSep 2, 2025
      If your Air-Con Air Conditioner's outdoor fan motor has locked rotor protection, check the following: * Ensure the outdoor fan motor connection is secure. * Check for any obstructions blocking the outdoor fan. * The fan motor might be faulty. * The outdoor control board might be faulty.
  • C
    catherinenixonSep 4, 2025
    What causes DC compressor start failure in Air-Con Air Conditioner?
    • S
      ssmithSep 4, 2025
      If your Air-Con Air Conditioner's DC compressor fails to start, it could be due to: * A faulty outdoor drive board. * A faulty compressor.
  • R
    Ricardo WilkinsonSep 7, 2025
    What to do if the outdoor EEPROM is in trouble in my Air-Con Air Conditioner?
    • L
      Lindsey AllenSep 7, 2025
      If your Air-Con Air Conditioner's outdoor EEPROM is in trouble, check: * If the EEPROM chip is loose. * If the EEPROM chip is inserted in the opposite direction. * If the EEPROM chip is faulty.
  • M
    Melissa GreenSep 9, 2025
    What to do if the outdoor coil temperature sensor is in trouble in my Air-Con Air Conditioner?
    • M
      Matthew BookerSep 9, 2025
      If the Air-Con Air Conditioner displays that the outdoor coil temperature sensor is in trouble, check the following: * Ensure the outdoor coil sensor is securely connected. * The outdoor coil temperature sensor might be faulty. * The outdoor control board might be faulty.

Summary

Safety Considerations

Product Specifications

Installation Instruction

Installation Place and Condition

Details recommended and avoided locations for indoor unit installation.

Refrigerant Flow System

Illustrates refrigerant flow for cooling and cooling/heating modes.

Air Purging and Leakage Test

Step-by-step guide for air purging and leak testing.

Test Running

Procedures for checking installation and performing operational tests, including post-installation checks and operation method.

Trouble Shooting

Error Code Table

Lists error codes and their potential causes indicated by LED lights.