  • M
    Mr. Timothy ReyesAug 18, 2025
    What to do if there is a communication failure between the indoor unit and outdoor unit in my Air-Con Air Conditioner?
    • L
      Luis KingAug 18, 2025
      If the Air-Con Air Conditioner displays a communication failure between the indoor and outdoor units, check the following: * Ensure the communication cable is securely connected. * Verify the communication cable is not faulty. * Check the connection between the filter board and the outdoor control board, ensuring it is correct and secure. * Check the connection between the filter board and the terminal, ensuring it is correct and secure. * The indoor control board might be faulty. * The PFC board might be faulty. * The power board might be faulty. * The outdoor control board might be faulty.
  • M
    Michael HolmesAug 20, 2025
    What causes current overload protection in Air-Con Air Conditioner?
    • T
      trevor30Aug 20, 2025
      If your Air-Con Air Conditioner is showing current overload protection, it might be due to: * Abnormal fan motor operation. * Dirty condenser and evaporator coils. * Abnormal air inlet or outlet conditions.
  • B
    Beth HunterAug 23, 2025
    Why does my Air-Con Air Conditioner show compressor exhaust temperature too high protection?
    • B
      Bryan GomezAug 23, 2025
      If your Air-Con Air Conditioner is showing compressor exhaust temperature too high protection, it could be due to: * A faulty compressor exhaust temperature sensor. * Insufficient refrigerant in the unit.
  • D
    donald13Aug 26, 2025
    What causes compressor shell temperature too high protection in Air-Con Air Conditioner?
    • J
      Joshua PatelAug 26, 2025
      If your Air-Con Air Conditioner is showing compressor shell temperature too high protection, it might be due to: * A loose connection of the compressor exhaust temperature sensor. * Insufficient refrigerant in the unit.
  • R
    Regina BurkeAug 28, 2025
    What to do if my Air-Con Air Conditioner shows anti-freeze or overload protection?
    • K
      katherine22Aug 28, 2025
      If the Air-Con Air Conditioner is experiencing anti-freeze protection during cooling or overload protection during heating, consider the following: * Check if the indoor coil temperature sensor is loosely connected. * The indoor coil temperature sensor might be faulty. * The indoor control board might be faulty. * The refrigerant system might be abnormal.
  • K
    Kenneth MatthewsAug 30, 2025
    What to do if the compressor drive is in trouble in my Air-Con Air Conditioner?
    • B
      Brandon HarveyAug 30, 2025
      If your Air-Con Air Conditioner's compressor drive is in trouble, possible causes include: * A faulty outdoor drive board. * A faulty compressor. * A faulty outdoor control board.
  • E
    Edward GarrettSep 2, 2025
    Why is the outdoor fan motor locked on my Air-Con Air Conditioner?
    • R
      Robin WilliamsSep 2, 2025
      If your Air-Con Air Conditioner's outdoor fan motor has locked rotor protection, check the following: * Ensure the outdoor fan motor connection is secure. * Check for any obstructions blocking the outdoor fan. * The fan motor might be faulty. * The outdoor control board might be faulty.
  • R
    Robin BradleySep 4, 2025
    What causes DC compressor start failure in Air-Con Air Conditioner?
    • A
      Ashley GoldenSep 4, 2025
      If your Air-Con Air Conditioner's DC compressor fails to start, it could be due to: * A faulty outdoor drive board. * A faulty compressor.
  • C
    catherinesmithSep 7, 2025
    What to do if the outdoor EEPROM is in trouble in my Air-Con Air Conditioner?
    • J
      Jose CampbellSep 7, 2025
      If your Air-Con Air Conditioner's outdoor EEPROM is in trouble, check: * If the EEPROM chip is loose. * If the EEPROM chip is inserted in the opposite direction. * If the EEPROM chip is faulty.
  • L
    Lynn AndersonSep 9, 2025
    What to do if the outdoor coil temperature sensor is in trouble in my Air-Con Air Conditioner?
    • E
      Eric EspinozaSep 9, 2025
      If the Air-Con Air Conditioner displays that the outdoor coil temperature sensor is in trouble, check the following: * Ensure the outdoor coil sensor is securely connected. * The outdoor coil temperature sensor might be faulty. * The outdoor control board might be faulty.

Summary

Safety Considerations

Important Reading and Precautions

Crucial preliminary instructions for safe operation, including special precautions and general guidelines.

Installation Guide

Installation Place and Conditions

Guidelines for selecting suitable indoor and outdoor unit locations.

Electric Wiring Diagram

Provides wiring schematics for indoor and outdoor units.

Air Purging and Leakage Test

Procedures for removing air and checking for refrigerant leaks.

Test Running Procedures

Steps to verify correct installation and operation after setup.

Trouble Shooting

Error Code Table

Lists error codes and their corresponding faults and root causes.

Air-Con ASRCI4H4S12 Specifications

General IconGeneral
BrandAir-Con
ModelASRCI4H4S12
CategoryAir Conditioner
LanguageEnglish

Related product manuals