IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electric shock and injury to person, including the following:
SAVE THESE INSTRUCTIONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you
have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer’s
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO
NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
a) Acceptable for use over a bathtub or shower when installed
in a GFCI protected branch circuit.
b) NEVER place a switch where it can be reached from a tub or
shower.
WARNING: DO NOT USE IN KITCHENS.
www.airkinglimited.com
210572050 Rev. D 1-11 1 of 8
Exhaust Fan
Models:
AS50, AS60, AS70 AS54

Questions and Answers:

Air King AS50 Specifications

General IconGeneral
ModelAS50
BrandAir King
Number of Speeds3
Voltage120V
Weather Resistant PanelYes
ThermostatNo
Remote ControlNo
Fan Size20 inches

Summary

General Safety Information

Reduce Fire, Shock, Injury Risks

Observe basic precautions like using the unit as intended and switching off power before servicing.

General Ventilation Use Caution

Use only for general ventilation, not for hazardous materials. Ensure proper ducting and grounding.

Speed Control Device Warning

Do not use this fan with any solid-state speed control device. Ensure use over tub/shower is GFCI protected.

Kitchen Use Warning

Explicitly states that the fan is not to be used in kitchens.

Installation Instructions

Preparing the Exhaust Fan

Unpack, identify parts, remove venturi assembly, choose location, and prepare knockout holes.

New Construction Installation

Guides flush mounting and securing the fan housing to joists or studs for new buildings.

Existing Construction Installation

Details tracing, cutting, and flush mounting the housing for existing structures.

Ducting Installation

Connect ducting to the collar and vent outdoors, adhering to building codes.

Wiring Installation

Connect house wiring to the fan's receptacle according to codes, ensuring power is off.

Completing the Installation

Reinstall Fan Venturi and Grill

Reinstall the fan venturi, secure it, check blower wheel spin, plug in the motor, and install the grill.

Use and Care

Cleaning the Grill

Clean the grill with mild detergent and a soft cloth; avoid abrasive materials.

Cleaning the Fan Assembly

Unplug unit, remove venturi, wipe parts with a dry cloth; never immerse electrical parts in water.

Troubleshooting Guide

Fan Not Operating

Check fuse, circuit breaker, motor plug connection, and wiring.

Slow Airflow

Inspect for obstructions in the exhaust ducting, such as bird nests.

Loud Operation

Check for loose motor, fan blade hitting housing, or other issues.

Limited Warranty

Warranty Coverage and Limitations

Details product coverage for defects, duration, exclusions, and liability limits.

Customer Service

Contact and Support Information

Provides phone number and website for product questions, service, and replacement parts.

Related product manuals