Summary

VOLU-flo/OAM II Transmitter Manual

General Information

Manual Purpose and Scope

Explains the manual's scope for installation, operation, and maintenance.

Airflow Measurement System Installations

Illustrates common system configurations for airflow measurement.

Product Specifications

Details technical specifications of the OAM II transmitter and sensors.

Operating Environment

Outlines environmental conditions for proper installation and operation.

Installation Guide

Site Selection Criteria

Provides criteria for choosing optimal installation locations for system components.

Enclosure Mounting

Details the process and requirements for mounting the OAM II transmitter enclosure.

Airflow Sensors

Describes the types of airflow sensors and their general placement.

Airflow Sensor Installation

Explains requirements and restrictions for installing airflow sensors at various inlet types.

Airflow Sensor Installation Details

Provides detailed diagrams and guidelines for installing airflow sensors.

Sensor Process Connections

Guides on connecting signal tubing for airflow sensors to the transmitter.

Power and Signal Connections

Details the terminal blocks for power input and signal connections.

Operation Overview

Transmitter Operating Modes

Explains the different operational modes available for the OAM II transmitter.

Display Options by Mode

Describes how display information varies across different operating modes.

Status Bar Indicators

Details the meaning of status indicators shown on the display.

Programming and Configuration

Main Menu Navigation

Overview of the main menu options for system setup and access.

Flow Settings Configuration

Configures system units, conditions, site elevation, velocity, and flow.

Flow Configuration Parameters

Sets inlet type, max flow, area, gain, and exponent for calculation.

Display Settings

Customizes display parameters like line content, timeout, and brightness.

Analog Output Settings

Configures output type and assigns parameters to analog outputs.

Filter and Lockdown Settings

Adjusts process and display filters, and sets lockdown values for signal smoothing.

Transducer Configuration

Selects installed transducers and their units for accurate pressure measurement.

Network Configuration

Sets up serial communication protocols like BACnet or MODBUS.

Field Characterization

Allows users to fine-tune calibration based on actual site conditions.

Service and Calibration Menu

Password Management

Manages system password for security and user access control.

Autozero Interval Settings

Enables and configures the automatic zeroing interval for pressure sensors.

Transducer Calibration

Guides users through the process of calibrating pressure transducers.

Analog Output Calibration

Details the procedure for calibrating the device's analog outputs.

Custom Device ID

Allows setting a custom alphanumeric identifier for the device.

Factory Settings Reset

Resets the system to its original factory default configuration.

Product Information

Displays system setup data, including serial number and firmware version.

Autozero and Output Test

Validates the functionality of autozero and analog outputs.

Communications Protocols

BACnet MS/TP Configuration

Details configuration for BACnet MS/TP serial communication.

Modbus RTU Configuration

Explains configuration and register map for Modbus RTU serial communication.

Maintenance and Care

Cleanliness

Guidelines for maintaining the cleanliness of the OAM II unit.

Mechanical Checks

Verifies secure signal connections and mounting hardware.

Electrical Checks

Inspects wiring for good connections and absence of corrosion.

Calibration Intervals

Recommends scheduling re-calibrations based on facility needs.

Troubleshooting Common Issues

0 FPM Display Troubleshooting

Solutions for when the display shows 0 FPM in Normal Mode.

Flow Exceeds Design Max Troubleshooting

Addresses issues where total flow exceeds the configured design maximum.

Fixed Temperature Value Troubleshooting

Solutions for a temperature reading that remains fixed.

Low Temperature Reading Troubleshooting

Explains that a very low temperature reading may indicate calibration or wiring issues.

Inaccurate Flow Readings Troubleshooting

Troubleshooting steps for inaccurate flow readings, including transducer sizing and calibration.

Warranty Information

Warranty Terms and Conditions

Outlines the terms and conditions of the product warranty.

Warranty Exclusions and Limitations

Lists conditions and actions that void the product warranty.