EasyManua.ls Logo

AirKing BFQ Series User Manual

AirKing BFQ Series
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
210572021 Rev. U 11-18 1 of 8
Exhaust Fan
BFQ, BFQW Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
injury to person, including the following:
WARNING:
TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING: TO REDUCE THE RISK
OF FIRE, ELECTRIC SHOCK AND INJURY TO
PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer’s guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION: FOR GENERAL VENTILATING USE ONLY.
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using exhaust fan.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
a) If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected to a
GFCI (Ground Fault Circuit Interrupter) – protected branch circuit.
b) Do not install wall mounted fans inside the shower area.
WARNING: DO NOT USE IN KITCHENS.
WARNING: THE DUCTING FROM THIS FAN TO THE
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT
ON THE AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE
THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH
SMALLER DUCTS THAN RECOMMENDED. INSULATION AROUND
THE DUCTS CAN REDUCE ENERGY LOSS AND INHIBIT MOLD
GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT
ACHIEVE THEIR RATED AIRFLOW.

Questions and Answers:

AirKing BFQ Series Specifications

General IconGeneral
BrandAirKing
ModelBFQ Series
CategoryFan
LanguageEnglish

Summary

General Safety Information

General Safety Precautions

Basic precautions for electrical appliances to reduce risk of fire, electric shock, and injury.

Specific Use and Installation Warnings

Warnings on solid-state controls, kitchen use, and ducting impact on fan performance.

SECTION 1 Preparing the Exhaust Fan

Unpack and Verify Components

Check all parts are present and prepare the wire compartment cover.

New Construction - BFQW Models (Oval Duct)

Mounting Bracket Installation (Oval Duct)

Align and secure the mounting bracket for BFQW models in new construction.

SECTION 2 New Construction - BFQ Models

Mounting Bracket Installation (BFQ)

Align and secure the mounting bracket for BFQ models in new construction.

SECTION 3 Existing Construction - BFQ Models

Ceiling/Wall Opening and Bracket

Cut opening and mount bracket for existing construction BFQ models.

SECTION 4 Ducting

Connecting and Sealing Ducts

Connect ducting securely to the fan and seal all joints for optimal performance.

SECTION 5 Wiring

Electrical Wiring Connections

Instructions for connecting house wiring to the fan receptacle.

SECTION 6 Completing the Installation

Final Installation Steps

Cover wire compartment, check blower, install grill, and restore power.

SECTION 7 Use and Care

Cleaning Instructions

Guidance on cleaning the grill and the fan assembly safely.

Troubleshooting Guide

Common issues with fan operation and suggested remedies.

LIMITED WARRANTY

Warranty Coverage and Limitations

Details on what the warranty covers, its duration, and exclusions.

Customer Service Information

Contact details and hours for customer support and part inquiries.

Related product manuals