Maintenance
2023 Flying Cloud 8-29
30FB Ofce Flying Cloud (50 Amp)
Main Circuit, 50 Amp
Circuit 1, 15 Amp
K Converter (Wired Direct) 8.0 Amps
Circuit 2, 20 Amp
B Front Air Conditioner 16.0 Amps
Circuit 3, 15 Amp (GFCI)
C Outside Receptacle 1.5 Amps
C Outside Receptacle - CSA 1.0 Amps
D Refrigerator Receptacle 2.7 Amps
E Dinette Receptacle 1.5 Amps
E Dinette Receptacle - CSA 1.0 Amps
F Galley Receptacle 1.5 Amps
F Galley Receptacle - CSA 1.0 Amps
G Bathroom Receptacle 1.5 Amps
G Bathroom Receptacle - CSA 1.0 Amps
Circuit 4, 20 Amp
H Rear Air Conditioner 16.0 Amps
Circuit 5, 15 Amp
J Microwave Receptacle 12.0 Amps
Circuit 6, 15 Amp
L CS Nightstand Receptacle 1.5 Amps
L CS Nightstand Receptacle - CSA 1.0 Amps
M RS Nightstand Receptacle 1.5 Amps
M RS Nightstand Receptacle - CSA 1.0 Amps
Circuit 7, 15 Amp
N Inverter Receptacle 0.0 Amps
P 1000 Watt Inverter 0.0 Amps
R Fwd Bedroom TV Receptacle 0.25 Amps
S Main Living Area TV Receptacle 0.25 Amps
T Aft Ofce Receptacle 1.5 Amps
T Aft Ofce Receptacle - CSA 1.0 Amps
U HDMI Receptacle 0.15 Amps
DC to AC 1000W Inverter Rated at 8.5 Amp
Inverting at 15 Amps
15 Amp Fuse for Overcurrent. Transfer Switch rated
at 15 Amp. UL 458 Tested. ULC