Expected temperature rise of the handled gas at maximum allowable pressure
differential and when operating at sea level is indicated below:
Table 7: Single Stage – Approximate Temperature Rise
Blower Model
Maximum Rise at 50 Hz speed Maximum Rise at 60 Hz speed
Degrees F Degrees C Degrees F Degrees C
3BA1100-7..0. 115 64 136 76
3BA1200-7..0. 65 36 101 56
3BA1300-7..0. 90 50 77 43
3BA1300-7..1. 90 50 140 78
3BA1300-7..2. 90 50 158 88
3BA1400-7..0. 99 55 86 48
3BA1400-7..1. 129 72 122 68
3BA1400-7..2. 149 83 167 93
3BA1500-7..0. 86 48 72 40
3BA1500-7..1. 115 64 97 54
3BA1500-7..2. 138 77 122 68
3BA1500-7..3. 203 113 180 100
3BA1500-7..6. 248 138 248 138
3BA1600-7..0. 81 45 68 38
3BA1600-7..1. 145 81 104 58
3BA1600-7..2. 171 95 176 98
3BA1600-7..3. 225 125 185 103
3BA1600-7..6. 248 138 194 108
3BA1600-7..7. 248 138 248 138
3BA1800-7..0. 104 58 104 58
3BA1800-7..1. 153 85 185 103
3BA1800-7..2. 248 138 221 123
3BA1900-7..0. 97 54 95 53
3BA1900-7..1. 182 101 155 86
3BA1900-7..3. 230 128 212 118
3BA1943-7..2. 85 47 75 42
3BA1943-7..3. 130 72 100 56
3BA1943-7..4. 180 100 140 78
3BA7210-0..1.. 126 70 142 79
3BA7310-0..1.. 142 79 142 79
3BA7310-0..2.. 178 99 187 104
3BA7410-0..1.. 194 108 214 119
3BA7510-0..1.. 199 111 232 129
3BA7510-0..2.. 248 138 234 130
3BA7610-0..1.. 244 136 255 142
3BA7610-0..3.. 244 136 255 142