NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
réf.409730 Type : SMVH09B-2A2A3NH
réf.409731 Type : SMVH12B-2A2A3NH
réf.409732 Type : SMVH18B-4A2A3NG
réf.409733 Type : SUV2-H18/3CFA-N + SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
réf.409894 Type : SUV3-H24/3CGA-N + 2 x SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
V3 12-2021
Nous vous remercions d’avoir choisi notre climatiseur
Pour assurer son bon fonctionnement et une utilisation de longue durée,
veuillez lire attentivement ce manuel avant toute utilisation et conservez le
Climatiseur à usage domestique
STARLIGHT - 255 bd de la Madeleine FR-06000 NICE
R32
Nouveau gaz réfrigérant
+ PERFORMANT
- DE POLLUTION
airton.fr
A
IRTON
NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
réf.409730 Type : SMVH09B-2A2A3NH
réf.409731 Type : SMVH12B-2A2A3NH
réf.409732 Type : SMVH18B-4A2A3NG
réf.409733 Type : SUV2-H18/3CFA-N + SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
réf.409894 Type : SUV3-H24/3CGA-N + 2 x SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
V3 12-2021
Nous vous remercions d’avoir choisi notre climatiseur
Pour assurer son bon fonctionnement et une utilisation de longue durée,
veuillez lire attentivement ce manuel avant toute utilisation et conservez le
Climatiseur à usage domestique
STARLIGHT - 255 bd de la Madeleine FR-06000 NICE
R32
Nouveau gaz réfrigérant
+ PERFORMANT
- DE POLLUTION
airton.fr
A
IRTON
NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
réf.409730
Type : SMVH09B-2A2A3NH
réf.409731
Type : SMVH12B-2A2A3NH
réf.409732
Type : SMVH18B-4A2A3NG
réf.409733
Type : SUV2-H18/3CFA-N + SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
réf.409894
Type : SUV3-H24/3CGA-N + 2 x SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
V3 12-2021
Nous vous remercions d’avoir choisi notre climatiseur
Pour assurer son bon fonctionnement et une utilisation de longue durée,
veuillez lire attentivement ce manuel avant toute utilisation et conservez le
Climatiseur à usage domestique
STARLIGHT - 255 bd de la Madeleine FR-06000 NICE
R32
Nouveau gaz réfrigérant
+ PERFORMANT
- DE POLLUTION
airton.fr
A
IRTON
NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
réf.409730 Type : SMVH09B-2A2A3NH
réf.409731 Type : SMVH12B-2A2A3NH
réf.409732 Type : SMVH18B-4A2A3NG
réf.409733 Type : SUV2-H18/3CFA-N + SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
réf.409894 Type : SUV3-H24/3CGA-N + 2 x SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
V3 12-2021
Nous vous remercions d’avoir choisi notre climatiseur
Pour assurer son bon fonctionnement et une utilisation de longue durée,
veuillez lire attentivement ce manuel avant toute utilisation et conservez le
Climatiseur à usage domestique
STARLIGHT - 255 bd de la Madeleine FR-06000 NICE
R32
Nouveau gaz réfrigérant
+ PERFORMANT
- DE POLLUTION
airton.fr
A
IRTON
NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
réf.409730 Type : SMVH09B-2A2A3NH
réf.409731 Type : SMVH12B-2A2A3NH
réf.409732 Type : SMVH18B-4A2A3NG
réf.409733 Type : SUV2-H18/3CFA-N + SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
réf.409894 Type : SUV3-H24/3CGA-N + 2 x SMVH09B-2A2A3NG + SMVHI2B-3A2A3NG
V3 12-2021
Nous vous remercions d’avoir choisi notre climatiseur
Pour assurer son bon fonctionnement et une utilisation de longue durée,
veuillez lire attentivement ce manuel avant toute utilisation et conservez le
Climatiseur à usage domestique
STARLIGHT - 255 bd de la Madeleine FR-06000 NICE
R32
Nouveau gaz réfrigérant
+ PERFORMANT
- DE POLLUTION
airton.fr
A
IRTON
INSTALLATIE-, INSTRUCTIE- EN ONDERHOUDSHANDLEIDING
AIRCONDITIONER/WARMTE- EN LUCHTPOMP
INSTALLATIONS-, BEDIENUNGS- & WARTUNGSANLEITUNG
KLIMAGERÄT / WÄRMEPUMPE LÜFTUNG
NOTICE D’INSTALLATION, D’INSTRUCTION & D’ENTRETIEN
CLIMATISEUR / POMPE A CHALEUR AIR/AIR
AIR CONDITIONER / AIR/AIR HEAT PUMP INSTALLATION,
INSTRUCTION & MAINTENANCE MANUAL
MANUAL DE INSTALACIÓN, INSTRUCCIONES Y MANTENIMIENTO
AIRE ACONDICIONADO/BOMBA DE CALOR/AIRE
MANUALE DI INSTALLAZIONE, ISTRUZIONE E MANUTENZIONE
CONDIZIONATORE D'ARIA / POMPA DI CALORE ARIA/ARIA

Table of Contents

Questions and Answers

  • L
    Louis PierceAug 17, 2025
    What to do if my Airton Air Conditioner does not work?
    • A
      andrewmcgrathAug 17, 2025
      If your Airton Air Conditioner isn't working, several factors could be the cause. First, verify that the appliance is properly plugged in and that there is a stable power supply. Check the thermomagnetic circuit breaker and reset it if necessary. Inspect all connections to ensure they are secure and properly plugged in. Look for any damage to the internal or external fan motor, and repair or replace it if needed. Also, check the voltage supply to ensure it matches the required voltage scale. If the TIMER ON function is activated, deactivate it. Finally, inspect the printed circuit board and replace it if damaged. If the operations have stopped to protect the appliance, follow the instructions to restart it. Also, replace the faulty thermal protection or fuse.
  • C
    Connie SnowAug 19, 2025
    Why is there insufficient airflow in my Airton Air Conditioner?
    • K
      kenneth08Aug 20, 2025
      Insufficient airflow in your Airton Air Conditioner can stem from several causes. Make sure the temperature setting is appropriate for cooling or heating. Check for and unblock any obstructions in the air inlets and outlets. Ensure that the air filter is clean; if dirty, clean or replace it. Verify that the fan speed isn't set too low and increase it if necessary. Also, consider whether there are other heat sources in the room that could be affecting the airflow, and remove or reduce them. Finally, check the refrigerant levels and refill if low.
  • D
    Daniel GarciaAug 22, 2025
    What to do if my Airton Air Conditioner is not responding to the remote?
    • S
      Stephen LeonAug 22, 2025
      If your Airton Air Conditioner isn't responding to the remote control, try these steps: First, ensure that you are close enough to the wall unit with the remote. Then, replace the remote control batteries. Finally, make sure there are no obstructions between the remote control and the appliance's receiver.
  • R
    Ricky BenitezAug 26, 2025
    How to get rid of a strange smell from my Airton Air Conditioner?
    • F
      Francisco AndersonAug 26, 2025
      A strange smell from your Airton Air Conditioner is likely due to a dirty air filter. Clean or replace the air filter to resolve this issue.
  • K
    Kristie LittleAug 28, 2025
    Why is the display not visible on my Airton Air Conditioner?
    • S
      samantha10Aug 28, 2025
      If the display on your Airton Air Conditioner is not visible, it could be due to a couple of reasons. First, check if the LIGHT function is activated and, if so, deactivate it. Also, verify that there is a stable power supply to the unit.
  • S
    stephaniebaileyAug 30, 2025
    How to fix an Airton Air Conditioner that does not work?
    • V
      virginia63Aug 31, 2025
      If your Airton Air Conditioner isn't working, start by checking the power supply and ensuring it's properly plugged in. Then, inspect the internal or external fan motor for damage and replace if needed. Also, check the thermomagnetic circuit breaker and reset or replace it. Replace any faulty thermal protection or fuse. Make sure all connections are secure. Identify and resolve any issues causing the appliance to stop as a protective measure. Use a voltmeter to check if the voltage is within the correct range. Deactivate the TIMER ON function, and inspect the printed circuit board for damage, replacing it if necessary.
  • J
    Jimmy HunterSep 2, 2025
    How to improve airflow in my Airton Air Conditioner?
    • H
      hartmanpaulSep 2, 2025
      If your Airton Air Conditioner isn't providing enough airflow in cooling or heating modes, first adjust the temperature setting. Check and clear any blockages in the air inlets and outlets. Clean or replace the dirty air filter. Increase the fan speed and remove or reduce other heat sources in the room. Finally, recharge the refrigerant if it's low.
  • M
    Mr. Christopher MorrowSep 5, 2025
    What to do if Airton Air Conditioner remote is not working?
    • J
      Jose SerranoSep 5, 2025
      If your Airton Air Conditioner is not responding to commands, move closer to the wall unit with the remote control. Replace the remote control batteries. Ensure there are no objects blocking the line of sight between the remote control and the receiver on the appliance.
  • M
    Michael MarshallSep 8, 2025
    How to get rid of strange smell from Airton Air Conditioner?
    • M
      moyerthomasSep 8, 2025
      If your Airton Air Conditioner emits a strange smell, the cause may be a dirty air filter. Clean or replace the air filter to resolve this issue.
  • T
    Todd GriffithSep 10, 2025
    Why does my Airton Air Conditioner sound like it's running water?
    • D
      David WilliamsSep 12, 2025
      The sound of running water in your Airton Air Conditioner is likely due to liquid backflow in the refrigerant circulation. To address this, check the refrigerant lines for proper flow and any obstructions.

Summary

General Instructions and Warnings

R32 Gas Safety Introduction

Installation Safety Rules

Installer Safety Guidelines

Installation Prohibitions

Location and Installation Choices

Indoor Unit Site Selection

Guidelines for selecting the location and installing the indoor wall unit.

Outdoor Unit Site Selection

Guidelines for selecting the location and installing the outdoor unit.

Electrical Power Supply Requirements

Ensuring a separate power supply circuit is used, specific to the air conditioner.

Indoor Unit Installation Process

Mounting Plate Installation

Steps for securely mounting the wall plate for the indoor unit.

Cable and Pipe Hole Drilling

Instructions for drilling holes in the wall for electrical and refrigeration connections.

Indoor Unit Connection Preparation

Refrigerant Line Connection Prep

Preparing the refrigerant lines for connection to the wall unit.

Condensate Drain Pipe Setup

Steps for installing the condensate pipe for proper drainage from the wall unit.

Outdoor Unit Installation Guide

Outdoor Unit Securing Method

Procedures for securely installing the outdoor unit on a wall or floor stand.

Outdoor Unit Drain Pipe Setup

Connecting the condensate pipe to the outdoor unit for drainage.

Refrigerant Connection Options

ReadyClim Option Details

Details on the ReadyClim option for easy, fast, and secure commissioning without vacuuming.

Multi-Split Refrigerant Connections

Electrical Connection Conditions

Indoor Unit Wiring Guide

Steps for making electrical connections to the indoor unit(s).

Unit-to-Unit Electrical Wiring

Final Installation Steps

Unit Maintenance and Cleaning

Airton SMVH09B-2A2A3NG Specifications

General IconGeneral
TypeSplit System
Cooling Capacity9000 BTU/h
Heating Capacity9500 BTU/h
RefrigerantR32
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz