What to do if my Airwell Air Conditioner has refrigerant leakage?
- Bbradley06Aug 6, 2025
If your Airwell Air Conditioner is experiencing refrigerant leakage, the system should be checked for leaks.
What to do if my Airwell Air Conditioner has refrigerant leakage?
If your Airwell Air Conditioner is experiencing refrigerant leakage, the system should be checked for leaks.
What to do if Airwell johnson JOAU-DKY012-H11 shows over voltage or over low voltage protection?
If your Airwell Air Conditioner is showing an over voltage or over low voltage protection error, make sure the voltage supply is correct.
How to troubleshoot indoor / outdoor units communication error in Airwell Air Conditioner?
If your Airwell Air Conditioner displays an indoor/outdoor units communication error, you should check the communication lines between the indoor and outdoor units.
What to do for condenser coil temperature sensor T3 open circuit in Airwell Air Conditioner?
If your Airwell Air Conditioner's condenser coil temperature sensor T3 has an open or short circuit, test or replace the condenser coil temperature sensor.
How to fix compressor discharge temperature sensor T5 issue in Airwell johnson JOAU-DKY012-H11?
If your Airwell Air Conditioner's compressor discharge temperature sensor T5 has an open or short circuit, test or replace the compressor discharge temperature sensor.
What to do if evaporator coil temperature sensor T2 is faulty in Airwell johnson JOAU-DKY012-H11?
If your Airwell Air Conditioner's evaporator coil temperature sensor T2 has an open or short circuit, test or replace the evaporator coil sensor.
How to troubleshoot indoor room temperature sensor T1 issue in Airwell johnson JOAU-DKY012-H11?
If your Airwell Air Conditioner's indoor room temperature sensor T1 has an open or short circuit, test or replace the temperature sensor.
Brand | Airwell |
---|---|
Model | johnson JOAU-DKY012-H11 |
Category | Air Conditioner |
Language | English |
Guidelines to prevent injury, damage, and hazards during operation and installation.
Detailed technical specifications for the 9K BTU indoor/outdoor unit pair.
Detailed technical specifications for the 12K BTU indoor/outdoor unit pair.
Detailed technical specifications for the 18K BTU indoor/outdoor unit pair.
Detailed technical specifications for the 24K BTU indoor/outdoor unit pair.
Provides physical dimensions and installation clearances for indoor units.
Illustrates installation clearances and dimensions for outdoor units.
Details on pipe sizing, maximum lengths, and elevation differences.
Steps for initial installation, including leak testing and evacuation.
Steps for re-installation involving indoor or outdoor unit repairs.
Details various protection mechanisms for compressor and unit operation.
Describes different operating modes like Cooling, Heating, and Fan.
Important safety warnings regarding electrical discharge before working on components.
List of indoor unit error codes and their meanings and solutions.
Diagnosis and solution for communication (E1) and fan speed (E3/F5) errors.
Diagnosis for sensor faults (E5/F1-F3) and leakage (EC).
Troubleshooting for overload (F0), voltage (P1), compressor (P2), and drive (P4) errors.