Airwell FLO 9 DCI - User Manual

Airwell FLO 9 DCI
94 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Multi Split Trio Quattro DCI
Indoor Units Outdoor Units
FLO 9 DCI
TRIO-72 DCI
QUTTRO-80 DCI
FLO 12 DCI
FLO 18 DCI
SX 9 DCI
SX 12 DCI
SX 18 DCI
BS 12 DCI
K 9 DCI
K 12 DCI
K 18 DCI
OCTOBER – 2008
REFRIGERANT
R410A
HEAT PUMP
SM TQDCI 1-A.1 GB
CONTENTS

Questions and Answers

  • T
    tara45Sep 12, 2025
    What does 'Outdoor Unit Fault' mean on my Airwell Air Conditioner?
    • H
      hunterjoshuaSep 12, 2025
      If your Airwell Air Conditioner displays an 'Outdoor Unit Fault', switch to outdoor diagnostics to identify the specific problem.
  • K
    kristen31Aug 25, 2025
    Why is my Airwell FLO 9 DCI Air Conditioner running but not cooling?
    • N
      ncookAug 25, 2025
      If your Airwell Air Conditioner seems to be running fine, but you're not getting any cooling or heating, there may be a refrigerant leak. You should check the refrigeration system for leaks.
  • P
    paguirreAug 25, 2025
    Why is my Airwell Air Conditioner not cooling or heating even though all components are operating?
    • K
      Kimberly MooreAug 26, 2025
      If your Airwell Air Conditioner's components are running but there's no cooling or heating, it's likely due to a refrigerant leak. Checking the refrigeration system is recommended.
  • M
    Matthew RogersSep 23, 2025
    Why is my Airwell FLO 9 DCI Air Conditioner compressor operating but not generating capacity?
    • C
      Carol SmithSep 23, 2025
      If the compressor in your Airwell Air Conditioner is running but one or more units aren't generating capacity, it could be due to an EEV (Electronic Expansion Valve) problem or refrigerant leakage.
  • A
    Austin CherrySep 12, 2025
    What does DC under voltage mean on my Airwell FLO 9 DCI?
    • H
      heathermontgomerySep 12, 2025
      If your Airwell Air Conditioner is showing a DC under voltage error, check the outdoor unit power supply voltage, as it indicates an electronics hardware problem.
  • J
    Jason HowardSep 16, 2025
    What to do if my Airwell Air Conditioner indoor fan does not start?
    • B
      Brandy ShannonSep 16, 2025
      If the indoor fan of your Airwell Air Conditioner doesn't start, first ensure the unit isn't in heat mode with a coil that's not yet warm; if so, switch to cool mode. Also, check if the outdoor unit is in the opposite mode and change the operation mode accordingly. Check power supply to motor is higher than 130VAC (for triack controlled motor) or higher than 220VAC for fixed speed motors, if OK replace capacitor, if not OK replace controller.
  • N
    Nicole PorterSep 4, 2025
    What causes sensor failures in my Airwell Air Conditioner?
    • M
      Michael EspinozaSep 5, 2025
      If you are experiencing sensor failures of any kind with your Airwell Air Conditioner, check the sensor connections or replace the sensor.
  • J
    Joseph LozanoSep 5, 2025
    What does communication mismatch mean on my Airwell FLO 9 DCI Air Conditioner?
    • J
      Jessica ScottSep 5, 2025
      If there's a communication mismatch with your Airwell Air Conditioner, it means the indoor and outdoor controllers have different versions. Replace the indoor controller to fix this.
  • E
    erik13Sep 17, 2025
    What to do if my Airwell Air Conditioner compressor motor is generating noise but no suction occurs?
    • S
      Sara CampbellSep 17, 2025
      If the compressor motor in your Airwell Air Conditioner is noisy but there's no suction, the phase order to the compressor is likely incorrect. You should check the compressor phase order.
  • L
    Lisa RyanAug 30, 2025
    Why is the power supply indicator not lighting up on my Airwell FLO 9 DCI Air Conditioner?
    • J
      Joseph AllenAug 30, 2025
      If the red LED power supply indicator on your Airwell Air Conditioner isn't lighting up, it suggests a power issue. Check the power supply to the unit. If the power supply is OK, check the display and display wiring. If those are OK, replace the controller.

Summary

Introduction to the Airwell Trio;Quattro DCI Series

Main Features of Trio;Quattro DCI

Details on High Technology and System Features, including R410A compatibility and IAQ.

Tubing Connections and Documentation

Information on flare type tubing and provided indoor unit manuals.

Product Data Sheets

Outdoor TRIO-72 DCI Specifications

Detailed technical specifications for the TRIO-72 DCI outdoor unit.

Outdoor QUATTRO-80 DCI Specifications

Detailed technical specifications for the QUATTRO-80 DCI outdoor unit.

Indoor Unit Specifications Overview

Specifications for FLO, K, SX, and BS series indoor units.

Rating Conditions

Operating Limits

Defines the operational temperature and voltage limits for cooling and heating modes.

Outline Dimensions

Indoor Unit Dimensional Drawings

Dimensional drawings for FLO, K, SX, and BS series indoor units.

Outdoor Unit Dimensional Drawings

Dimensional drawings for TRIO-72 and QUATTRO-80 DCI outdoor units.

Performance Data

TRIO-72 DCI Outdoor Unit Performance

Cooling and heating performance data for Trio-72 DCI with various combinations.

QUATTRO-80 DCI Outdoor Unit Performance

Cooling and heating performance data for Quattro-80 DCI with various combinations.

Indoor Unit Performance Data

Cooling/Heating factors and correction factors for all indoor units.

Tubing Length Capacity Correction Factor

Correction factors for cooling and heating based on tubing length.

Model Correction Factors & Calculation Example

Correction factors by model and examples for capacity calculations.

Pressure Curves

TRIO-72 DCI Pressure Curve Data

Pressure curves for TRIO-72 DCI in cooling and heating modes.

QUATTRO-80 DCI Pressure Curve Data

Pressure curves for QUATTRO-80 DCI in cooling and heating modes.

Pressure Correction Factors and Calculations

Factors for tubing length, ODU code, and calculation examples.

Electrical Data

Trio-72, Quattro-80 DCI Electrical Specifications

Electrical specifications for Trio-72 and Quattro-80 DCI outdoor units.

Wiring Diagrams and Electrical Connections

Outdoor Unit Wiring Diagrams and Connections

Wiring diagrams and electrical connection details for outdoor units.

Refrigeration Diagrams

TRIO-72 DCI, QUATTRO-80 DCI Refrigerant System Diagram

Refrigerant system diagram for Trio-72 and Quattro-80 DCI outdoor units.

Tubing Connections

Tubing Connection Details and Torque Values

Information on tubing parts, bending, and connection torque specifications.

Control System

Control System Overview and Components

Block diagram, compressor, fan, RV, EEV, HMI, dry contacts, sensors, base heater.

Operating Rules, Initialization, and Communication

Initialization process, IDU setup, and communication/temp failure handling.

Indoor Unit Operation and Control Features

Fan control, modes, heating, dry contact, unit indicators.

System Operation Modes, Compressor, and Protections

Run mode, compressor/fan speed, EEV, RV, base heater, protections, deicing.

Installation and Technician Test Modes

Procedures for installation testing and technician diagnostic modes.

User Interface, Keys, and Menu Navigation

UI description, key functions, main menu, and submenus.

Jumper Settings for OFAN and Compressor

Definitions and settings for OFAN and compressor jumpers.

Indoor Unit Software Parameters and Settings

General and model-dependent SW parameters for indoor units.

Troubleshooting

System Troubleshooting: Failures and Diagnostics

General failures, ODU/IDU diagnostics, and fault codes.

Troubleshooting: Checking Key System Components

Procedures for checking voltage, fuse, motor, compressor, EEV, etc.

Exploded Views and Spare Parts Lists

Outdoor Unit Exploded Views and Parts Lists

Visual breakdowns and parts lists for Trio-72 and Quattro-80 DCI outdoor units.

Appendix A

Installation and Operation Manual Details

Contains details for the installation and operation manual.

Airwell FLO 9 DCI Specifications

General IconGeneral
TypeSplit System
Cooling Capacity2.6 kW
RefrigerantR32
Energy Efficiency Ratio (EER)3.21
Power Supply220-240V, 50Hz
Outdoor Unit Weight23 kg
Noise LevelOutdoor: 50 dB(A)
Outdoor Unit Dimensions (WxHxD)700 x 500 x 240 mm