Airwell WDI 9 - User Manual

Airwell WDI 9
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
DUO 38 DCI / DAKOTA
Indoor Units Outdoor Units
WDI 7
DUO 38 DCI
WDI 9
WDI 12
JUNE – 2009
REFRIGERANT
R410A
HEAT PUMP
SM DUO38I 1-A.2 GB

Questions and Answers

  • K
    Kevin KingAug 9, 2025
    Why is my Airwell Air Conditioner compressor running but not cooling?
    • M
      millswilliamAug 9, 2025
      If your Airwell Air Conditioner's compressor is running, but the unit isn't cooling, the Electronic Expansion Valve (EEV) might be stuck in the closed position. You should check the EEV.
  • N
    Nathaniel SmithAug 16, 2025
    What to do if one Airwell Air Conditioner indoor unit is not cooling and the other is leaking?
    • N
      Nathaniel ObrienAug 16, 2025
      If one Airwell Air Conditioner indoor unit is operating in cool mode but has no cooling capacity, while the other unit has water leaks or freezing problems, the communication wires between the two indoor units may be switched. Check and correct the communication wire connections.
  • J
    Jason ChavezAug 23, 2025
    What to do if the Airwell WDI 9 Air Conditioner indoor fan won't start?
    • J
      Jack CarneyAug 23, 2025
      If the indoor fan of your Airwell Air Conditioner doesn't start, but the louvers are open and the green LED is lit, here are a few things to check: * If the unit is in heat mode, the coil may not be warm yet. Try switching to cool mode. * The outdoor unit might be in the opposite mode. Change the operation mode and see if the fan starts. * There may be a problem with the PCB or capacitor. Set the fan to high speed and check the power supply to the motor. For Triac controlled motors, it should be higher than 130VAC; for fixed speed motors, it should be higher than 220VAC. If the power supply is OK, replace the capacitor. If not, replace the controller.
  • M
    Michael DavisAug 31, 2025
    How to fix an Airwell WDI 9 when the power indicator is off?
    • S
      Steven GrimesAug 31, 2025
      If the power supply indicator (Red LED) on your Airwell Air Conditioner indoor unit isn't lit, it indicates a power supply problem. Check the power supply from the outdoor unit. If the power supply is OK, then check the display and display wiring. If the display and wiring are OK, replace the controller.

Summary

Introduction to DUO 38 DCI

Product Data Sheet

Outdoor Unit Specifications

Technical specifications for the DUO 38 DCI outdoor unit.

Rating Conditions

Performance Data

WDI 7-7 DCI Performance Data

Cooling/heating capacity and power input for WDI 7-7 DCI.

WDI 9-9 DCI Performance Data

Cooling/heating capacity and power input for WDI 9-9 DCI.

WDI 9-12 Performance Data

Cooling/heating capacity and power input for WDI 9-12.

Pressure Curves

Wiring Diagrams

DUO 38 DCI Wiring Diagram

Electrical wiring diagram for the DUO 38 DCI outdoor unit.

Refrigeration Diagrams

Control System

Protections and Fault Handling

Details on unit protections, fault codes, and deicing/overflow.

Troubleshooting

System Failures and Corrective Actions

Common failure symptoms and corrective actions.

MSMP Diagnostics and Fault Codes

Interpretation of MSMP fault codes for units.

Exploded Views and Spare Parts Lists

Airwell WDI 9 Specifications

General IconGeneral
BrandAirwell
ModelWDI 9
CategoryAir Conditioner
LanguageEnglish