CN Fixed RPM Series
REFRIGERANT
R410A
HEATPUMP
REV: 01 Oct 2008

Questions and Answers

  • B
    Brandi SimmonsAug 15, 2025
    What to do if my Airwell Air Conditioner does not respond to remote control?
    • C
      Cynthia BennettAug 15, 2025
      If the Airwell Air Conditioner unit does not respond to the remote control command, it could be that the remote control command didn't reach the indoor unit. First, check the remote control batteries. If the batteries are OK, check the display and display wiring. If those are OK, replace the PCB.
  • R
    Ronald MataAug 18, 2025
    How to reset filter light on Airwell Air Conditioner?
    • D
      Daniel HicksAug 18, 2025
      When the filter LED comes ON on your Airwell Air Conditioner after 512 hours of operation, it means the air filter is clogged. Replace the air filter and then press the RESET button.
  • B
    Benjamin McclainAug 21, 2025
    Why is my Airwell Air Conditioner working in the wrong mode?
    • S
      Samantha MillerAug 21, 2025
      If the Airwell Air Conditioner unit works in the wrong mode (cooling instead of heating, or heating instead of cooling), the issue could stem from the electronics or the power connection to the RV. First, check the RV power connections. If those are OK, test the RV operation using a direct 230 VAC power supply. If it then works correctly, replace the outdoor controller.
  • B
    Billy GuerreroAug 25, 2025
    What to do if Airwell Air Conditioner compressor is on but outdoor fan is not working?
    • T
      Tasha WashingtonAug 25, 2025
      If the Airwell Air Conditioner's compressor is running but the outdoor fan isn't working, it could be due to a problem with the outdoor electronics or the outdoor fan capacitor. To troubleshoot, switch the unit to COOL mode, HIGH speed with 16 degrees set point (in summer) or HEAT mode high speed with 30 degrees set point (in winter). Check that the power supply to the motor is higher than 130 VAC. If it is OK, replace the capacitor; if not, replace the controller.
  • A
    Aaron MorrisAug 27, 2025
    Why Airwell Air Conditioner indoor fan works when unit is off?
    • J
      jacob88Aug 27, 2025
      If the indoor fan of your Airwell Air Conditioner is running even when the unit is OFF, and you can't change the fan speed with the remote control, it's likely a PCB problem. To fix this, replace the controller.
  • T
    turnerheatherAug 30, 2025
    Why is my Airwell Air Conditioner compressor motor noisy?
    • J
      Jennifer SullivanAug 30, 2025
      If the compressor motor in your Airwell Air Conditioner is noisy and there's no suction, it could be due to the wrong phase order to the compressor. Check the compressor phase order to resolve this.
  • C
    Cathy YoungSep 2, 2025
    Why Airwell CN 9 Air Conditioner indoor fan does not start?
    • R
      Ronald RoseSep 2, 2025
      If the indoor fan of your Airwell Air Conditioner isn't starting, but the louvers are open and the Green LED is lit, it could be due to a couple of reasons. First, if the unit is in HEAT MODE and the coil isn't warm yet, change to COOL MODE to check if the fan starts. Alternatively, there might be a problem with the PCB or capacitor. To check this, change to HIGH speed and see if the power supply to the motor is higher than 130 VAC. If it is OK, replace the capacitor; if not, replace the controller.
  • D
    Dylan ChangSep 5, 2025
    Why is my Airwell Air Conditioner leaking water inside?
    • D
      Dustin RodgersSep 5, 2025
      If water is leaking from the indoor unit of your Airwell Air Conditioner, it's likely that the drainage tube is blocked. Check the drainage tube and clear any blockages.
  • J
    Justin UnderwoodSep 8, 2025
    Why Airwell CN 9 Air Conditioner power supply indicator does not light up?
    • A
      Adam YoungSep 8, 2025
      If the power supply indicator (Red LED) on your Airwell Air Conditioner isn't lighting up, it indicates there's no power supply. Check the power supply first. If the power supply is OK, check the display and display wiring. If those are OK, replace the PCB.
  • S
    Sharon DixonSep 12, 2025
    What to do if Airwell CN 9 responds to remote but operate indicator does not light up?
    • M
      Melissa SmithSep 12, 2025
      If the Airwell Air Conditioner unit responds to remote control commands, but the operate indicator (Green LED) doesn't light up, it indicates an issue with the display PCB. Replace the display PCB to resolve this.

Summary

Introduction and Specifications

Introduction to the Series

Overview, main features, and unit components.

Product Data Sheet

Detailed technical specs, ratings, and dimensions for models.

Rating Conditions and Dimensions

Specifies operating conditions, limits, and unit dimensions.

Performance and Technical Data

Performance Data and Curves

Details capacity, pressure curves, and sound levels.

Electrical Data and Wiring

Provides electrical specifications and wiring requirements.

Refrigeration and Tubing

Shows refrigeration diagrams and tubing connection details.

Control System and Operation

Electronic Control System

Explains electronic control, jumpers, modes, and diagnostics.

Protections and Fault Handling

Covers unit protections, thermistor operations, and fault handling.

Operating Modes

Details cooling, heating, dry, auto, sleep, and timer functions.

Troubleshooting and Installation

Troubleshooting Guide

Provides solutions for common problems and malfunctions.

Exploded Views and Spare Parts

Shows exploded views and lists spare parts for all units.

Installation Procedures

Details unit mounting, electrical, tubing, panel, and duct installation.

Operation Manual Highlights

Key features, tips, modes, protections, and maintenance.