Airwell Dakota WDI 9 - User Manual

Airwell Dakota WDI 9
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
TRIO DAKOTA 5.2 DCI
Indoor Units Outdoor Units
DAKOTA WDI 7
TRIO DAKOTA 5.2 DCI
DAKOTA WDI 9
DAKOTA WDI 12
JUNE – 2009
REFRIGERANT
R410A HEAT PUMP
SM TRIO52 1-A.2 GB
CONTENTS

Questions and Answers

  • J
    Johnny BanksAug 4, 2025
    Why is my Airwell Dakota WDI 9 Air Conditioner not communicating?
    • P
      Patrick GonzalezAug 4, 2025
      A lack of communication in your Airwell Air Conditioner is possibly due to mis-wiring between the indoor unit (IDU) and outdoor unit (ODU). Check the connection between the IDU and ODU to resolve this issue.
  • M
    Michael HensleyAug 12, 2025
    What does it mean if my Airwell Air Conditioner heat sink is overheating?
    • M
      Matthew PhillipsAug 12, 2025
      If your Airwell Air Conditioner's heat sink is overheating, it indicates a normal AC protection mechanism is active. To resolve this, turn off the system and wait for 30 minutes. Then, turn the system back on. If the issue persists, further assistance is needed.
  • J
    Jessica PayneAug 17, 2025
    How to fix illegal ODU Model error on Airwell Air Conditioner?
    • C
      Corey WhiteAug 17, 2025
      If your Airwell Air Conditioner displays an illegal ODU Model error, it means the ODU Model jumper setting is wrong. To fix this, check the jumper setting according to the model table on the controller label.
  • B
    brandon68Aug 21, 2025
    What to do if OCT is disconnected in Airwell Dakota WDI 9 Air Conditioner?
    • E
      Erik MillerAug 21, 2025
      If the OCT is disconnected in your Airwell Air Conditioner: 1. Reinstall the OCT and ensure it's well-connected. 2. If the fault persists, use a multimeter to check the OCT's resistor. If it's +?, the OCT is damaged; replace it. 3. If it's around 10K (at 25 ), proceed to case 3 and replace the controller.
  • M
    mcguirescottAug 26, 2025
    What to do if OCT is shorted in Airwell Dakota WDI 9 Air Conditioner?
    • A
      ashley82Aug 27, 2025
      If the OCT is shorted in your Airwell Air Conditioner: 1. Use a multimeter to check the OCT's resistor. If it's 0, the OCT is damaged; replace it. 2. If it's around 10K (at 25 ), the controller is shorted; replace the controller.
  • R
    rileysusanAug 29, 2025
    How to troubleshoot a red LED that doesn't light up on my Airwell Dakota WDI 9?
    • C
      charrisAug 29, 2025
      If the power supply indicator (Red LED) does not light up on your Airwell Air Conditioner's indoor unit, the cause may be no power supply. Check the power supply from the outdoor unit. If the power supply is OK, check the display and display wiring. If these are OK, replace the controller.
  • M
    michaelwalshNov 7, 2025
    What to do if my Airwell Air Conditioner indoor fan does not start?
    • J
      joseph30Nov 7, 2025
      If the louvers are opened, the green LED lights up, but the indoor fan of your Airwell Air Conditioner doesn't start, consider the following potential causes: the unit might be in heat mode without coil warmth (change to cool mode to check); the outdoor unit could be in the opposite mode (change the operation mode); there could be a problem with the PCB or capacitor (change to high speed and check power supply to motor, if OK replace capacitor, if not OK replace controller); the jumper settings of the outdoor unit might be incorrect (use diagnostics information on MSMP board); or the communication wires of the two indoor units are switched, the EEV is stuck in close position or communication problems exist (check and correct the communication wires connection, check EEV, use diagnostics in...

Summary

INTRODUCTION

PRODUCT DATA SHEET

Outdoor Unit: TRIO DAKOTA 5.2 kw DCI

Detailed technical specifications for the TRIO DAKOTA 5.2kw DCI outdoor unit, including capacity, power, dimensions, etc.

Indoor Units Data

Technical specifications for the DAKOTA WDI 7 DCI indoor unit, covering airflow, sound levels, dimensions, etc.

DAKOTA WDI 12 DCI Specifications

Technical specifications for the DAKOTA WDI 12 DCI indoor unit, including airflow, sound levels, dimensions, etc.

PERFORMANCE DATA

TRIO DAKOTA 9+9+9

Provides cooling capacity data for TRIO DAKOTA 9+9+9 configurations under various conditions.

TRIO DAKOTA 9+9+12

Presents cooling capacity data for TRIO DAKOTA 9+9+12 configurations.

TRIO DAKOTA 12+12

Provides cooling capacity data for TRIO DAKOTA 12+12 configurations.

Cooling Capacity (kW) - Run Mode

Table of cooling capacity (kW) for TRIO DAKOTA 12+12 under different operating temperatures.

Heating Capacity (kW) - Run Mode

Details heating capacity (kW) for TRIO DAKOTA 12+12 based on operating temperatures.

PRESSURE CURVES

Cooling - Test Mode

Graphs of suction and discharge pressure vs. outdoor temperature for cooling.

Heating - Test Mode

Graphs for suction and discharge pressure vs. outdoor temperature in heating mode.

ELECTRICAL DATA

Single Phase Units

Electrical specifications for single-phase units, including power supply, current, and circuit breaker details.

WIRING DIAGRAMS

TRIO 5.2 DAKOTA DCI

Provides the wiring diagram for the TRIO 5.2 DAKOTA DCI system, showing connections for indoor and outdoor units.

TUBING CONNECTIONS

Tubing Connections Guidelines

Provides guidelines for tubing connections, including torque values and diagrams.

CONTROL SYSTEM

Compressor Frequency Control

Details how compressor frequency is controlled via NLOAD settings and power shedding.

NLOAD setting

Explains NLOAD setting based on indoor fan speed and outdoor unit calculation.

Target Frequency Setting

Describes how target frequency is set based on NLOAD and outdoor air temperature.

Indoor Fan Control

Details the 10 indoor fan speeds and auto fan operation.

Heating Element Control

Conditions for starting and stopping the heating element.

Outdoor Fan Control

Describes the 7 outdoor fan speeds and control routines based on operating conditions.

EEV (electronic Expansion valve) Control

Explains the control logic for the electronic expansion valve (EEV).

Protections

Lists the 5 protection codes and how the MSMP calculates overall protection status.

Indoor Coil Defrost Protection

Describes the ICT trend for indoor coil defrost protection.

TROUBLESHOOTING

ELECTRICAL & CONTROL TROUBLESHOOTING

Provides troubleshooting steps for electrical and control system issues.

Dual Split System Failures and Corrective Actions

Lists common symptoms, probable causes, and corrective actions for dual split systems.

Judgment by MSMP Diagnostics

Explains how to interpret MSMP diagnostics and fault codes.

MSMP Fault Code for Outdoor unit:

Lists MSMP fault codes for the outdoor unit with possible reasons and corrective actions.

MSMP Fault Code for Indoor Unit:

Lists MSMP fault codes for indoor units with possible reasons and corrective actions.

Precaution, Advise and Notice Items

Important safety precautions and advice for handling the unit.

High voltage in Outdoor unit controller.

Warning about high voltage in the outdoor unit controller and safety advice.

EXPLODED VIEWS AND SPARE PARTS LISTS

Airwell Dakota WDI 9 Specifications

General IconGeneral
Cooling Capacity2.6 kW
Power Supply220-240V, 50Hz
RefrigerantR32
TypeWall Mounted
Power Consumption (Cooling)810 W
Outdoor Noise Level50 dB