EasyManua.ls Logo

Airwell Trio Dakota 5.2 DCI User Manual

Airwell Trio Dakota 5.2 DCI
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
TRIO DAKOTA 5.2 DCI
Indoor Units Outdoor Units
DAKOTA WDI 7
TRIO DAKOTA 5.2 DCI
DAKOTA WDI 9
DAKOTA WDI 12
JUNE – 2009
REFRIGERANT
R410A HEAT PUMP
SM TRIO52 1-A.2 GB
CONTENTS

Questions and Answers:

Airwell Trio Dakota 5.2 DCI Specifications

General IconGeneral
Cooling Capacity5.2 kW
RefrigerantR32
Energy Efficiency Ratio (EER)3.21
Coefficient of Performance (COP)3.61
Noise Level (Outdoor Unit)52 dB(A)
TypeSplit System
Power Supply220-240V, 50Hz

Summary

INTRODUCTION

General

Overview of the Trio 5.2 DAKOTA DCI outdoor unit and its capabilities.

Main Features

Lists key features of the high efficiency multi split inverter unit.

Tubing Connections

Details on the required flare type interconnecting tubing for installation.

Inbox Documentation

Information on manuals supplied with each indoor unit.

Matching Table

Table showing compatible indoor units for the outdoor unit.

PRODUCT DATA SHEET

Outdoor Unit: TRIO DAKOTA 5.2kw DCI

Technical specifications for the TRIO DAKOTA 5.2kw DCI outdoor unit.

DAKOTA WDI 7 DCI Specifications

Technical data for the DAKOTA WDI 7 DCI indoor unit.

DAKOTA WDI 9 DCI Specifications

Technical data for the DAKOTA WDI 9 DCI indoor unit.

DAKOTA WDI 12 DCI Specifications

Technical data for the DAKOTA WDI 12 DCI indoor unit.

Indoor Units Combinations

Data on various cooling and heating capacity combinations of indoor units.

RATING CONDITIONS

Operating Limits

Specifies the operating temperature and voltage limits for cooling and heating.

OUTLINE DIMENSIONS

Indoor Unit: DAKOTA WDI 7/9 DCI

Dimensional drawings for the DAKOTA WDI 7 and 9 DCI indoor units.

Indoor Unit: DAKOTA WDI 12 DCI

Dimensional drawings for the DAKOTA WDI 12 DCI indoor unit.

Outdoor Unit: TRIO DAKOTA 5.2 DCI

Dimensional drawings for the TRIO DAKOTA 5.2 DCI outdoor unit.

PERFORMANCE DATA

TRIO DAKOTA 9+9+9

Performance data for the TRIO DAKOTA 9+9+9 configuration.

Cooling Capacity (kW) - Run Mode

Cooling capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of capacity correction factors.

Heating Capacity (kW) - Run Mode

Heating capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of heating capacity correction factors.

TRIO DAKOTA 9+9+12

Performance data for the TRIO DAKOTA 9+9+12 configuration.

Cooling Capacity (kW) - Run Mode

Cooling capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of capacity correction factors.

Heating Capacity (kW) - Run Mode

Heating capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of heating capacity correction factors.

TRIO DAKOTA 12+12

Performance data for the TRIO DAKOTA 12+12 configuration.

Cooling Capacity (kW) - Run Mode

Cooling capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of capacity correction factors.

Heating Capacity (kW) - Run Mode

Heating capacity in kW for run mode under various temperature conditions.

Capacity Correction Factors

Graphical representation of heating capacity correction factors.

Capacity Correction Factor Due to Tubing Length (OneWay)

Factors affecting performance based on tubing length.

DAKOTA WDI 7/9/12 DCI

Tubing length correction factors for specific indoor unit models.

Cooling

Cooling performance correction factors vs. tubing length.

Heating

Heating performance correction factors vs. tubing length.

PRESSURE CURVES

Model: Trio DAKOTA WDI 9+9+9

Pressure curves for the Trio DAKOTA WDI 9+9+9 model.

Cooling - Test Mode

Suction and discharge pressure curves for cooling mode.

Heating - Test Mode

Suction and discharge pressure curves for heating mode.

Model: Trio DAKOTA WDI 9+9+12

Pressure curves for the Trio DAKOTA WDI 9+9+12 model.

Cooling - Test Mode

Suction and discharge pressure curves for cooling mode.

Heating - Test Mode

Suction and discharge pressure curves for heating mode.

Model: Trio DAKOTA WDI 12+12

Pressure curves for the Trio DAKOTA WDI 12+12 model.

Cooling - Test Mode

Suction and discharge pressure curves for cooling mode.

Heating - Test Mode

Suction and discharge pressure curves for heating mode.

ELECTRICAL DATA

Single Phase Units

Electrical specifications and wiring details for single-phase units.

WIRING DIAGRAMS

TRIO 5.2 DAKOTA DCI

Detailed wiring diagram for the TRIO 5.2 DAKOTA DCI system.

REFRIGERATION DIAGRAMS

Heat Pump Models

Refrigeration circuit diagrams for heat pump models.

TRIO 5.2 DAKOTA => Cooling & Heating Mode

Refrigerant flow diagram for cooling and heating modes.

TUBING CONNECTIONS

Tubing Installation and Torque Specifications

Guidelines for tubing installation, bending, and torque values.

CONTROL SYSTEM

General Functions and Operating Rules

Overview of DCI software and parametric functions.

System Operation Concept

Explains the communication and capacity request flow between units.

Compressor Frequency Control

Details NLOAD setting and compressor frequency management.

Indoor Fan Control

Describes indoor fan speed settings and turbo speed activation.

Heating Element Control

Conditions for starting and stopping the heating element.

Outdoor Fan Control

Explains outdoor fan speed control based on conditions.

EEV (electronic Expansion valve) Control

Control logic for the electronic expansion valve.

Reversing Valve (RV) Control

Operation of the reversing valve in heating mode.

Electro Static Filter (ESF) Control

Conditions for ESF activation.

Base Heater Control

Conditions for base heater activation based on OAT.

Fan Mode

Indoor fan operation in manual and auto modes.

Cool Mode

NLOADI calculation and fan speed adjustment in cool mode.

Heat Mode

NLOADI calculation and fan speed adjustment in heat mode.

Auto Cool/Heat Mode

Automatic switching between cool and heat modes.

Dry Mode

Operational parameters for dry mode.

Protections

Overview of protection codes and their meanings.

Indoor Unit Dry Contact (excluding Delta range)

Functions of indoor unit dry contact based on J8 selection.

Operating the Unit from the Mode Button

Forced operation modes and pre-set temperatures.

On Unit Controls and Indicators

Explanation of indoor unit controls, indicators, and LED display functions.

Test Mode

Procedures for entering and operating in test mode.

Unit Operation in Test Mode

Fixed settings for unit operation during test mode.

TROUBLESHOOTING

ELECTRICAL & CONTROL TROUBLESHOOTING

Troubleshooting guide for electrical and control issues.

Dual Split System Failures and Corrective Actions

Table of common symptoms, causes, and corrective actions.

Checking the Refrigeration System

Procedures for checking system pressures and performance curves.

Judgment by MSMP Diagnostics

Interpreting MSMP diagnostics and fault codes.

judgment by Mega Tool

Using Mega Tool for system monitoring and diagnostics.

Simple Procedures for Checking the Main Parts

Basic checks for mains voltage, power input, PCB, fan motor, etc.

EXPLODED VIEWS AND SPARE PARTS LISTS

Outdoor Unit: TRIO DAKOTA 5.2 kw DCI

Exploded view diagram of the outdoor unit.

Outdoor Unit: TRIO DAKOTA 5.2kw DCI R410A

Detailed spare parts list for the outdoor unit.

APPENDIX A

INSTALLATION AND OPERATION MANUAL

Reference to the installation and operation manual for the unit.

Related product manuals