Details the key technological innovations and benefits of the PNX DCI series.
Provides detailed technical specifications for the PNX 9 DCI model, including indoor and outdoor unit data.
Provides detailed technical specifications for the PNX 12 DCI model, including indoor and outdoor unit data.
Provides detailed technical specifications for the PNX 18 DCI model, including indoor and outdoor unit data.
Provides detailed technical specifications for the PNX 21 DCI model, including indoor and outdoor unit data.
Provides detailed technical specifications for the PNX 24 DCI model, including indoor and outdoor unit data.
Presents cooling and heating capacity data for PNX 9 / GC 9 DCI units.
Presents cooling and heating capacity data for PNX 12 / GC 12 DCI units.
Presents cooling and heating capacity data for PNX 18 / GC 18 DCI units.
Presents cooling and heating capacity data for PNX 21 / GC 21 DCI units.
Presents cooling and heating capacity data for PNX 24 / GC 24 Z DCI units.
Details electrical data for single-phase units, including power supply, current, and cable specifications.
Provides wiring diagrams for indoor and outdoor units of PNX 9, 12 and GC 9, 12 DCI models.
Wiring diagram for PNX 18 and 21 DCI indoor units.
Wiring diagram for GC 18 and 21 DCI outdoor units.
Wiring diagrams for PNX 24 DCI indoor and GC 24 DCI outdoor units.
Detailed wiring diagram for the GC 24 Z DCI outdoor unit.
Refrigeration diagram for cooling mode.
Refrigeration diagram for heating mode.
Refrigeration diagrams for PNX 24 / GC 24 Z DCI in cooling and heating modes.
Illustrates electrical connections for PNX 9, 12, 18, 21 DCI indoor units.
Illustrates electrical connections for the PNX 24 DCI indoor unit.
Details how NLOAD settings affect compressor frequency and limits.
Defines how target frequency is set based on NLOAD and outdoor air temperature.
Describes EEV opening calculation and correction based on compressor temperature.
Lists and describes the five protection codes used by the unit.
Describes condensate water overflow protection logic.
Explains jumper settings for operation, self-test, compensation, and family selection.
Lists software parameters for indoor and outdoor units.
Details how NLOAD settings affect compressor frequency and limits.
Defines how target frequency is set based on NLOAD and outdoor air temperature.
Explains EEV control for DCI50/60 and GC 24/24Z/30 models.
Lists and describes various protection mechanisms.
Lists software parameters for indoor and outdoor units.
Provides troubleshooting steps for common failures in GC 9-24Z DCI series.
Provides troubleshooting steps for GC 24/30 DCI models.