EasyManua.ls Logo

Airzone EASYZONE AZEZ6FUJST - User Manual

Airzone EASYZONE AZEZ6FUJST
108 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
rebmuNegaPdraobpilC
EASYZONE
Quick Installation Guide
Español
English
Français
Italiano
Português
Deutsch

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Airzone EASYZONE AZEZ6FUJST and is the answer not in the manual?

Summary

Warnings and Environmental Policy

Precautions

Safety instructions for handling the system, including avoiding wet hands and disconnecting power.

Environmental Policy

Guidelines for proper disposal and recycling of electronic equipment to protect the environment.

General Requirements

Installation and System Checks

Essential steps and verification before and during installation, including technician qualifications.

Introduction

System Overview and Thermostat Types

Explains Airzone system capabilities and recommends Blueface thermostats for advanced features.

Thermostat Interface Identification

How to identify Master vs. Zone interfaces based on visual cues on Blueface and Think thermostats.

System Installation

Easyzone Assembly

Guidance on assembling the Easyzone unit, including insulation and component numbering.

Assembly to Indoor Unit

Detailed steps for attaching the Easyzone unit to the indoor HVAC unit.

Ventilation Air Intake Assembly

Instructions for modifying the ventilation air intake components for proper airflow.

Thermostat Assembly and Connection

Steps for mounting Airzone thermostats and connecting them to the system.

Main Control Board Connection

Details on connecting various system elements to the main control board.

Wiring and Powering

Covers thermostat connections, system powering, and connecting peripherals.

System Management and Evaluation

Reset Procedures

How to reset zones, the entire system, or change thermostat batteries.

Assembly and Connection Evaluation

Checks for LEDs and system components after installation to ensure correct operation.

Initial Configuration

Blueface and Think Thermostats Setup

Step-by-step guide for configuring Blueface and Think thermostats, including language and zone settings.

Lite Thermostat Configuration

Instructions for initial setup of the Airzone Lite thermostat, including wireless device association.

Configuration Evaluation

Verifying the correct functioning of the system after initial configuration.

System Tuning and Settings

Flow Adjustment (REG)

How to adjust the maximum opening of dampers for optimal airflow in each zone.

Minimum Air Setting (A-M)

How to set the minimum opening of dampers for correct air flow.

Advanced Settings

Blueface Thermostat Advanced Menu

Accessing and navigating the advanced settings on Blueface thermostats.

Think Thermostat Advanced Menu

Accessing and navigating the advanced settings on Think thermostats.

System Parameters

System Address and Supermaster

Setting system number and imposing operation mode on other systems.

Temperature Range and Hysteresis

Setting temperature limits and defining differential for heating.

Damper, Standby, Relay & Return Temp

Configuring damper types, standby logic, boiler control, and return temperatures.

Q-Adapt and Unit Control Algorithms

Selecting algorithms for Direct Expansion and Fancoil units.

Zone Parameters

Associated Outputs and Thermostat Settings

Linking control outputs and defining thermostat roles (Master/Zone).

Use Mode and Control Stages

Setting thermostat operational mode and configuring heating/cooling stages.

Offset and Thermostat Reset

Adjusting room temperature and resetting individual thermostats.

Annex

Bypass Damper Assembly

Step-by-step instructions for installing a bypass damper.

Annul Damper Procedures

Instructions for nullifying dampers on adapters and plenums.

Summary

Warnings and Environmental Policy

Precautions

Safety instructions for handling the system, including avoiding wet hands and disconnecting power.

Environmental Policy

Guidelines for proper disposal and recycling of electronic equipment to protect the environment.

General Requirements

Installation and System Checks

Essential steps and verification before and during installation, including technician qualifications.

Introduction

System Overview and Thermostat Types

Explains Airzone system capabilities and recommends Blueface thermostats for advanced features.

Thermostat Interface Identification

How to identify Master vs. Zone interfaces based on visual cues on Blueface and Think thermostats.

System Installation

Easyzone Assembly

Guidance on assembling the Easyzone unit, including insulation and component numbering.

Assembly to Indoor Unit

Detailed steps for attaching the Easyzone unit to the indoor HVAC unit.

Ventilation Air Intake Assembly

Instructions for modifying the ventilation air intake components for proper airflow.

Thermostat Assembly and Connection

Steps for mounting Airzone thermostats and connecting them to the system.

Main Control Board Connection

Details on connecting various system elements to the main control board.

Wiring and Powering

Covers thermostat connections, system powering, and connecting peripherals.

System Management and Evaluation

Reset Procedures

How to reset zones, the entire system, or change thermostat batteries.

Assembly and Connection Evaluation

Checks for LEDs and system components after installation to ensure correct operation.

Initial Configuration

Blueface and Think Thermostats Setup

Step-by-step guide for configuring Blueface and Think thermostats, including language and zone settings.

Lite Thermostat Configuration

Instructions for initial setup of the Airzone Lite thermostat, including wireless device association.

Configuration Evaluation

Verifying the correct functioning of the system after initial configuration.

System Tuning and Settings

Flow Adjustment (REG)

How to adjust the maximum opening of dampers for optimal airflow in each zone.

Minimum Air Setting (A-M)

How to set the minimum opening of dampers for correct air flow.

Advanced Settings

Blueface Thermostat Advanced Menu

Accessing and navigating the advanced settings on Blueface thermostats.

Think Thermostat Advanced Menu

Accessing and navigating the advanced settings on Think thermostats.

System Parameters

System Address and Supermaster

Setting system number and imposing operation mode on other systems.

Temperature Range and Hysteresis

Setting temperature limits and defining differential for heating.

Damper, Standby, Relay & Return Temp

Configuring damper types, standby logic, boiler control, and return temperatures.

Q-Adapt and Unit Control Algorithms

Selecting algorithms for Direct Expansion and Fancoil units.

Zone Parameters

Associated Outputs and Thermostat Settings

Linking control outputs and defining thermostat roles (Master/Zone).

Use Mode and Control Stages

Setting thermostat operational mode and configuring heating/cooling stages.

Offset and Thermostat Reset

Adjusting room temperature and resetting individual thermostats.

Annex

Bypass Damper Assembly

Step-by-step instructions for installing a bypass damper.

Annul Damper Procedures

Instructions for nullifying dampers on adapters and plenums.

Airzone EASYZONE AZEZ6FUJST Specifications

General IconGeneral
CompatibilityAirzone systems
Maximum number of zones6
Operating temperature0°C to 50°C
Weight200 g
Control InterfaceTouchscreen
Power supply24V AC
Storage temperature-20°C to 60°C
Humidity Range5% to 95% RH, non-condensing
TypeZone control system

Related product manuals