RESIDENTIAL SALT WATER CHLORINE GENERATOR
Classic Series
INSTRUCTION MANUAL
This manual is for:
CLASSIC RP MODEL RANGE
FEATURING REVERSE POLARITY TECHNOLOGY
RP-15, RP-20, RP-25, RP-36, RP-50, RP-64, RP-80
CLASSIC LS MODEL RANGE
(RP20-3500ppm, RP25-3500ppm, RP35-3500ppm)
MIDI RANGE
(RP-100, RP-150)
Includes:
TIME CLOCK MODELS (battery backup optional)
POOL LIGHT MODELS (where fi tted)

Questions and Answers

  • J
    Jessica HollandAug 12, 2025
    Why is my AIS Water Filtration System chlorine generator not producing enough chlorine?
    • B
      Brandi ThomasAug 12, 2025
      If your AIS Water Filtration System's chlorine generator isn't producing enough chlorine, there are several potential causes. First, the chlorine production level might be set too low; try adjusting the control knob clockwise to increase production. Second, the generator may not be running for a sufficient amount of time; increase the operation running time. A calcified electrode can also reduce chlorine output, so you should clean the electrode. Finally, incorrect water chemistry can impact chlorine generation, so ensure your water chemistry is properly balanced.
  • S
    shawn18Aug 15, 2025
    What to do if the low salinity light is on or flashing on my AIS Water Filtration System?
    • R
      Rachel BoydAug 15, 2025
      If the low salinity light is flashing on your AIS Water Filtration System, it typically indicates that the water salinity is too low. Have the salinity level tested by a pool professional and increase it if necessary. Another possible cause is a calcified electrode, which requires cleaning. A faulty electrode may also be the reason, so have it tested and replaced if necessary.
  • J
    Jeanne VargasAug 20, 2025
    Why are there no lights on my AIS Water Filtration System chlorine generator and the pump is not running?
    • B
      billyfordAug 20, 2025
      If there are no lights on your AIS Water Filtration System's chlorine generator and the pump isn't running, the first thing to check is the power supply. Unplug the chlorine generator from the power and test the outlet with another working appliance to ensure there is power. Another possibility is that the time clock is in a designated off period, or the switch is in the OFF position; switch to BYPASS to circumvent TIMER or OFF functions.
  • W
    wardaustinAug 23, 2025
    What to do if Status Light (3) is flashing and the generator is beeping on my AIS Water Filtration System?
    • D
      Dylan JacobsAug 23, 2025
      If Status Light (3) is flashing and the generator is beeping on your AIS Water Filtration System, it could be due to a few reasons. One possibility is that the pump isn't running, the filtration is blocked, or there's an air lock. A large air bubble in the electrode housing can trigger this alarm, so clean out the skimmer box, check and clear any blockages, and re-prime the pump. Another potential cause is that the electrode lead isn't properly plugged in; double-check that the electrode lead plug is securely connected to the electrode.
  • A
    Anthony TorresAug 27, 2025
    Why is the high salinity light on or flashing on my AIS Water Filtration System?
    • S
      samantha63Aug 27, 2025
      If the high salinity light is on or flashing on your AIS Water Filtration System, it typically means the pool salinity is too high. Have the salinity level tested by a pool professional and decrease it if necessary. If the salinity level is within the correct range, the chlorine generator may be faulty. In this case, contact your dealer or AIS Water for assistance.
  • K
    Kyle SimpsonAug 30, 2025
    Why is the circuit breaker tripping on my AIS Water Filtration System?
    • H
      hleAug 30, 2025
      If the circuit breaker is tripping for your AIS Water Filtration System, it could be due to several reasons. A mains power surge may be the cause; set the machine to off and push the circuit breaker. A fault with shorted electrodes could also be the problem; visually inspect the electrode and check for foreign or conductive surfaces. If found, remove and clean the cell. If neither of these resolves the issue, there may be a fault with the power supply, in which case you should contact your dealer or AIS Water.
  • T
    Tammy HinesSep 3, 2025
    Why is Status Light (3) on and the pump is running, but no other lights are on, on my AIS Water Filtration System?
    • M
      Michael DukeSep 3, 2025
      If Status Light (3) is on and the pump is running, but no other lights are on, on your AIS Water Filtration System, it could mean that the chlorine generator production is turned off. To resolve this, adjust the control knob clockwise to increase production.
  • E
    Erin LivingstonSep 7, 2025
    What causes white powdery material on the pool bottom with my AIS Water Filtration Systems?
    • J
      Jonathan JonesSep 7, 2025
      If you notice a white powdery material on the bottom of your pool when using the AIS Water Filtration System, it's likely due to excessive water hardness. Test the water chemistry and adjust accordingly to resolve this issue.

Summary

System Overview and Models

Model Range Introduction

Introduces the Classic, LS, and MIDI ranges of AutoChlor units.

Disclaimer and Recommendations

Includes legal disclaimers and recommendations for genuine parts.

Unit Components

Control Panel Overview

Identifies and briefly describes the main components and controls on the unit.

Installation Procedures

Cell Housing Installation

Guidelines for plumbing the chlorinator cell housing into the pool system.

Power Supply Installation

Instructions on how and where to mount the AutoChlor power supply unit.

Operation and Controls

Salt Addition and Water Balance

Guidance on calculating and adding salt, and maintaining water chemistry.

Chlorine Production Factors

Explains how climate affects chlorine production.

Power Supply Controls

Details on the circuit breaker, on/off switch, and pump socket.

Warning Indicator Lights

Interpretation of various indicator lights for system status.

Chlorine Controller and Output

How to use the chlorine controller and interpret output indicators.

Timer and Bypass Operation

How to operate the timer functions and bypass switch.

General Chlorinator Operation

Steps for initial startup, operation, and setting output.

Chlorinator Running Times

Factors determining the optimal running time for the chlorinator.

Maintenance and Troubleshooting

Electrode Maintenance

Recommended inspection, removal, and cleaning of the electrode.

Troubleshooting Common Issues

Guide to diagnosing and resolving common problems with the unit.

Specific Troubleshooting Scenarios

Addresses issues like salinity levels, hardness, and circuit breaker trips.

Warranty and Contact Information

Warranty Information

Information on warranty coverage and terms.

Contact and Support Details

How to contact for warranty issues or general assistance.

AIS AutoChlor RP-20 Specifications

General IconGeneral
BrandAIS
ModelAutoChlor RP-20
CategoryWater Filtration Systems
LanguageEnglish