4. Error&Protection Code
Fault phenom eno n
The humidity always shows "25%RH" (there is a big difference from the actual humidity)
The humidity always shows "99%RH" (there is a big difference from the actual humidity)
Analysis of causes
The humidity sensor failure?
1. There is water on the surface of the humidity sensor?
2. The humidity sensor failure?
Processing Method
Set the humidity to 30%RH, if the dehumidifier can still continue to work, the
machine can be used normally.
Repair and replace the humidit y sen sor.
If the dehumidifier is not affected and can continue to work, the machine can be
used normally.
please let the dehumidifier keeps working for a period of time, after the water on
the surface of the humidity sensor is removed, it will return to work normally.
Repair and replace the humidity sensor.
Notice:
When an error happened, there will be an error code flashes on the display. If
there is more than one error, each error code will be displayed in turn, if there is
only one error, the error code and the current humidity value will be displayed
alternately.
07