Run the machine where air can be supplied in a stable condition.
Use after-cooler or similar equipment to supply clean air at all times.
Operation Procedures
Supply Air
Check whether air pressure is set at the
required level for main regulator and other
regulators as below.
① Main Regulator ・・・0.5MPa
② Side Expander Cylinder ・・・0.3MPa
Low air pressure can cause a malfunction. If the pressure does not reach its standard level,
set the air pressure properly following the procedure below.
Check Point
Check compressor if the main air pressure does not reach 0.5MPa even after the above adjustment
①
②
Follow the procedure for proper operation.
Improper operation can cause mechanical failure or injury to operators.
CAUTION
■ How to adjust air pressure
1. Pull the adjustment knob up.
2. Turn the knob to adjust air pressure
Clockwise → Pressure will increase
Counterclockwise →Pressure will decrease
3. Push the knob down.
Attention!