AUDIO
OSCILLATOR
1,000Hz
AC
RL=8
OHMS
VOLTMETER
Fig.
10
Instrument
Connections
for
Power
Meter
Sensitivity
Adjustment
SPEAKER
OUT
DC
VOLTMETER
Fig.
11
Instrument
Connections
for
Center
Off-set
1.
POWER
METER
SENSITIVITY
ADJUSTMENT
(Refer
to
Figs.
8,
10)
Set
the
Meter
Range
switch
to
“x1”,
and
connect
the
load
resistor
(RL=8
ohms)
to
speaker
terminals.
Then
apply
a
IkHz
signal
to
the
AUX
input
ter-
minals,
adjusting
the
input
level
so
as
to
obtain
the
rated
output
voltage
level
(12.6V)
at
both
ends
of
the
load
resistor.
Adjust
VR3
(left
channel)
and
VR3b
(right
channel)
on
the
Pre
Amp
P.C
Board
so
that
the
7th
LED
(20
Watts)
in
the
Power
Meter
light
up.
34
Voltage
Adjustment
2.
SENTER
OFF-SET
VOLTAGE
ADJUSTMENT
(Refer
to
Figs.
9,
11)
Connect
the
DC
Voltmeter
or
Digital
Voltmeter
to
the
speaker
terminals.
Adjust
the
VR1
(left
channel)
and
VR1b
(right
channel)
on
the
Main
Amp
P.C
Board,
so
that
the
Voltmeter
reads
0
t50mV.