MODEL NO.
PSM250-405
SPECIFICATION
REVISION
01
DATE
2005.03.14
REV: 01 PAGE. 8
tacking time of 5V,18V and 24V.
3.2.8. All of main outputs tracking time should under 20ms
4. PROTECTION:
4.1. Input protection:
The input power line will be fused with a 4A / 250Vac fuse.
4.2. Over voltage protection:
By used a latch mode, the output shall be protected from over voltage fault at all conditions
including open-loop by breakdown that is set to trip as following table.
4.3. Short circuit protection:
The output will withstand a short circuit across the outputs with latch-off function, Output can be
shorted without damage.
Item CH1 CH2 CH3 CH4
Output Voltage +5V +5Vsb +18V +24V
Over voltage protection 6.5-7 Auto restart 22.-25.3 27.6-31.2
Over current protection 4.5A 1.5A 4.5A 10A
4.6. Over current protection:
By auto restart mode,
4.7. Over thermal protection: